■ PROCEDURE OF ADJUSTMENT
1) Connect the transceiver and PC with the OPC-1529R.
2) Turn ON the transceiver.
3) Boot up Windows, and click the program group 'CS-A210/A220 ADJ' in the 'Programs' folder of the [Start] menu, then the
CS-A210/A220 ADJ's window appears.
4) Click the [ADJ] icon to enter the adjustment mode.
5) Click the [READ] icon to load the initial data from the transceiver.
6) Set or modify the adjustment data as specified in the guidances (pages 4-3 to 4-10).
7) When the adjustment is finished, click the [WRITE] icon.
8) Click the [NRM] icon to quit the adjustment mode, and return to the normal mode.
• ADJUSMENT SOFTWARE SCREEN
<CS-A210 ADJ>
[WRITE]
[ADJ]
[NRM]
[LOAD]
Adjustment
items
*This screen is an example.
<CS-A220 ADJ>
[WRITE]
[ADJ]
[NRM]
[LOAD]
Adjustment
items
*This screen is an example.
(Replacement page)
4-2g
Select the adjustment channel
for each adjustment item.
Frequency
CH No.
(MHz)
AM Low
118.000
AM Mid
127.500
AM High 136.975
FM Low
161.650
FM High
163.275
Select the adjustment channel
for each adjustment item.
Frequency
CH No.
(MHz)
AM Low
118.000
AM Mid
127.500
AM High 136.975
FM Low
161.650
FM High
163.275