Icom IC-A210 Service Manual page 106

Hide thumbs Also See for IC-A210:
Table of Contents

Advertisement

August 2015
M PROCEDURE OF ADJUSTMENT
q Connect the transceiver and PC with the OPC-1529R.
w Turn ON the transceiver.
e Boot up Windows, and click the program group 'CS-A210/A220 ADJ' in the 'Programs' folder of the [Start] menu,
then the CS-A210/A220 ADJ's window appears.
r Click the [ADJ] icon to enter the adjustment mode.
t Click the [READ] icon to load the initial data from the transceiver.
y Set or modify the adjustment data as specifi ed in the guidances (pages 4-3 to 4-6).
u When the adjustment is fi nished, click the [WRITE] icon.
i Click the [NRM] icon to quit the adjustment mode, and return to the normal mode.
• ADJUSMENT SOFTWARE SCREEN
<For the IC-A210>
[WRITE]
[NRM]
[ADJ]
[LOAD]
Adjustment
items
*This screen is an example.
• ADJUSMENT SOFTWARE SCREEN
<For the IC-A220>
[WRITE]
[NRM]
[ADJ]
[LOAD]
Adjustment
items
*This screen is an example.
(Replacement page)
Select the adjustment channel
for each adjustment item.
Select the adjustment channel
for each adjustment item.
4-2
Frequency
CH No.
(MHz)
AM LOW
118.000
AM MID
127.500
AM HIGH 136.975
FM LOW
161.650
FM HIGH 163.275
CH No. Frequency
(MHz)
AM LOW 118.000
AM MID
127.500
AM HIGH 136.975
FM LOW 161.650
FM HIGH 163.275