Important Safety And Installation Instructions; Product Introduction; Transformer+Lights - emaux UNDERWATER LIGHT Series Installation And Operation Manual

Table of Contents

Advertisement

1. IMPORTANT SAFETY AND INSTALLATION INSTRUCTIONS

Please read the manual carefully before commencing installation. This manual contains important
information about the correct installation and operation of lights.
1. Only qualified electrician is allowed to carry out the installation of this product.
2. Avoid direct contact with electrical power.
3. Respect all regulations in effect for preventing accidents.
4. All units are required to be disconnected from the main electricity before any operation of maintenance.
5. For safe and proper installation, ensure that those parts supplied with the produce are used.
6. Never handle with wet hands and feet.
7. This unit is design for use only when fully submerged in fresh water, connecting with a safety transformer
8. This product should be installed according to your local electrical installation ordinances and regulations.
9. Due to the corrosive nature of unbalanced pool chemicals, please keep you pool water is acid-base balanced
prior to installation, and ensure the longevity of these lights.
10. If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the
manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
11. Check that there is enough cable behind light to allow for servicing above water, preferably at ground-level
pool-side.
12. Never operate this Underwater Light for more than 1 minute unless it is totally submerged in water.
13. You lights require cleaning at any time, be sure to a mild detergent or other ways that don't damage to the
lights.
14. Be sure power is off before installing or removing light. Allow light to cool before replacing.
15. Maximum Depth for Light installation at 1.2 meter.
16. Maximum Water Temperature Range for light operation 0-25°C
For non replacable lightsources: "The light source of this luminaire is not replaceable; when the light source
reaches its end of life the whole luminaire shall be replaced".
For operation only with safety isolating transformer conforming with AS/NZS 61558 series.

2. PRODUCT INTRODUCTION

2.1 TRANSFORMER+LIGHTS

When the light is connected to the transformer directly, to on /off the main switch to controls the color changes.
For LED-P100/TP100/CP100 RGB, When it's different colors, turn off the lights, wait 3-5S and turn on the lights,
it's the same colors.