Instructing The Homeowner; Installation Verification - Johnson Controls XAF Series Installation Manual

Full cased and uncased coils for cooling and heat pumps
Table of Contents

Advertisement

Table 12: XAU airflow data (CFM)
Models
400
XAUC42E
0.02
XAUC48F
0.01
XAUC60G
0.01
XAUD60G
0.01
XAUD60H
0.01
Note:
- Airflow data is for dry coil conditions only, tested without filters.
- For optimal performance, external static pressures of 0.2 in. W.C. to 0.6 in. W.C. are recommended.
Applications above 0.6 in. W.C. are not recommended.
Table 13: XAU airflow data (CFM) - downflow
Models
400
XAUA18A
0.07
XAUA24B
0.06
XAUB30C
0.05
XAUB36D
0.04
XAUC42E
0.03
XAUC48F
0.02
XAUC60G
0.02
XAUD60G
0.01
XAUD60H
0.02
Note:
- Airflow data is for dry coil conditions only, tested without filters.
- For optimal performance, external static pressures of 0.2 in. W.C. to 0.6 in. W.C. are recommended.
Applications above 0.6 in. W.C. are not recommended.

Instructing the homeowner

When the installation is complete, do the following:
Assist the homeowner with registering
the unit warranty using the warranty card
included with the unit or (preferably) online at
www.upgproductregistration.com. It is best practice
to complete a startup sheet showing the critical
readings of the unit at the time of commissioning.
This startup sheet can be uploaded as part of the
online registration process.
Instruct the homeowner that the indoor coil drain
pan must be inspected and cleaned regularly to
prevent odors and ensure proper drainage.
Installation Manual: XAF, XAH, and XAU Series - Full Cased and Uncased Coils for Cooling and Heat Pumps
600
800
1000
External static pressure (in. W.C.)
0.04
0.08
0.11
0.04
0.07
0.10
0.03
0.05
0.08
0.02
0.04
0.06
0.03
0.06
0.08
600
800
1000
External static pressure (in. W.C.)
0.16
0.26
n/a
0.13
0.23
0.34
0.09
0.15
0.21
0.09
0.16
0.24
0.06
0.11
0.15
0.05
0.09
0.13
0.04
0.08
0.12
0.03
0.06
0.09
0.04
0.07
0.11
Johnson Controls Ducted Systems
CFM
1200
1400
0.16
0.21
0.14
0.19
0.12
0.16
0.09
0.12
0.12
0.18
CFM
1200
1400
n/a
n/a
n/a
n/a
0.29
n/a
0.33
0.45
0.22
0.28
0.19
0.27
0.17
0.23
0.13
0.17
0.16
0.22

Installation verification

Before installation, review the installation aids that follow.
During installation, use these installation aids to verify
that tasks are completed as required.
TXV checklist
□ Is the coil metering device installed correctly?
□ Is the correct TXV installed according to the Technical
Guide or Tabular Data Sheet for the outdoor section?
□ Is the TXV temperature bulb positioned correctly?
□ Is the TXV temperature bulb insulated?
□ Is the equalizer line connected?
1600
1800
2000
0.27
n/a
n/a
0.24
0.30
n/a
0.22
0.27
0.33
0.15
0.19
0.23
0.22
0.26
0.31
1600
1800
2000
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
0.38
n/a
n/a
0.34
0.43
n/a
0.30
0.38
0.47
0.23
0.28
0.34
0.28
0.34
0.42
33