Salicru EQUINOX EQX 5000-2T Quick Manual page 8

Solar inverters
Table of Contents

Advertisement

3.
Insert the metal terminals into the MC4 connectors, until you hear a click. Once this is done, pull gently on the cable to make sure
it is correctly attached.
4.
Screw the cap onto the body of each connector, making sure all of the elements fit together perfectly and that the rubber seals seal
the cable with the connector:
Use the special spanners for
MC4 connectors in order to
ensure optimum tightening
without damaging the
connectors.
5.
values shown in the following table:
Maximum DC input power (W)
Maximum DC input voltage (VDC)
Operating range (VDC)
MPPT range (VDC)
MPPT trackers / inputs per MPPT
Max. input current per MPPT x no. of MPPTs
Max. short-circuit current per MPPT (Isc PV) x no. of MPPTs
8
Check the polarity and voltage of the photovoltaic panels before connecting them to the inverter, in line with the
Specifications
Inverter model
EQX 5000-2T
EQX 8000-2T
5500
8800
900
200-800
260-800
350-800
2/1
10 A x 2
12 A x 2
11 A x 2
13 A x 2
EQX 10000-2T
11000
1000
400-800
12,5 A x 2
14 A x 2