3 Installation; Installation Environment - Delta BX6.3 DD Operation And Installation Manual

Residential battery storage system
Hide thumbs Also See for BX6.3 DD:
Table of Contents

Advertisement

Installation
3 Installation
- Do not install BX6.3_DD near or on flammable surfaces.
- Please mount BX6.3_DD tightly on a solid / smooth surface.
- Install BX6.3_DD in a location that prevents damage from flooding.
- Do not expose BX6.3_DD to ambient temperatures above 60°C or below -10°C.
- Operating or storing BX6.3_DD in temperatures outside its specified range might
cause damage to BX6.3_DD.
The chapter contains instructions for (1) Installation environment
(2) Mechanical installation; (3) Electrical Installation; (4) Communication setup.

3.1 Installation Environment

- The optimal temperature range for BX6.3_DD to operate is -10° to 45°C.
- If the ambient temperature is outside the optimal operating range, BX6.3_DD
will be de-rating.
- The operating humidity is within the range from 0 to 95%.
- BX6.3_DD may limit charge or discharge power based on battery cell temperature
to improve battery lifespan.
- If the ambient temperature is outside the operating range, BX6.3_DD stops to
protect itself from any unexpected damage.
BX6.3_DD is designed to be waterproof and can be installed both indoors and
outdoors. However, please avoid exposure to direct sunlight, high temperature
and high humidity if installed outdoors.
Please avoid using in the following condition; otherwise the device may malfunction.
• Locations where IP65 isn't satisfied.
• Locations where temperature changes severely.
• Locations where the device is directly exposed to saltwater, sea breezes and
high humidity.
• Locations that are or might be affected by explosive, combustible, corrosive
and other poisonous gases.
• Location exposed dust and dirt.
• Location with poor ventilation.
• Locations with other special conditions.
• At altitude above 2000m.