Safety Instructions; Handling Of Prohibitions - Delta BX6.3 DD Operation And Installation Manual

Residential battery storage system
Hide thumbs Also See for BX6.3 DD:
Table of Contents

Advertisement

Safety

1.2.3 Safety Instructions

The battery storage system should not be installed in direct sunlight or on flammable
surfaces. Please be sure to mount the battery storage system tightly on a solid /
smooth surface. The optimal temperature range for the battery storage system to
operate is 10 to 30°C . The operating humidity is within the range from 0 to 95%.
If the ambient temperature is outside the operating range, the battery storage
system stops to protect itself from any unexpected damage.
This battery storage system should be installed by a trained and experienced
installer designated by the retailer. Having the product installed by a non-specialized
installer is very dangerous and can cause damage or injury. The battery storage
system is always installed by 2 or more people. (According to regional regulation,
more people may be required.)
Please make sure any breaker is turned off before connecting cables. Be careful
of the cable length must be less than 100 meters.

1.2.3.1 Handling of Prohibitions

The battery module contains flammable materials such as organic solvents.
Mishandling the battery module may cause fire, smoke, or an explosion and
the battery module's functionality will be seriously damaged. Protection circuits
are designed into the battery storage system via BMSS (PCB part inside the
battery cabinet) to protect the battery modules.