Figure 28. Fan installation
Table 17. Fan installation
Rubber mounting pin
1
Step 1.
Align the fan with the slot in the fan cage; then, place the fan into the slot. Make sure the fan cable
goes in the cable slot, under the rubber mounting pin as shown.
Step 2.
Connect the fan cable to the connector by pressing it down until it clicks.
Note: Each fan has a corresponding cable connector on system board. Make sure you connect the
cable to the right connector (see
After you install the fan, complete the following steps:
1. Reinstall the air baffle if it was removed (see
2. Install the top cover onto the server (see
3. Install the server into the rack if necessary.
4. Reconnect power cords and all external cables.

Install the simple-swap drive backplate

Use this information to install the drive backplate.
Before you install a simple-swap drive backplate, complete the following steps:
1. Read
"Safety" on page iii
To install the simple-swap drive backplate, complete the following steps:
Notes: There are three types of backplate supported by the server, all are removed and installed in a similar
method.
• Two 3.5-inch drive backplate
• Four 3.5-inch drive backplate (connects to onboard connectors)
"System-board connectors" on page
"Install the air baffle" on page
"Install the top cover" on page
and
"Installation Guidelines" on page 32
Fan cable
2
53).
54).
to ensure that you work safely.
Chapter 3
16).
.
Server hardware setup
39