Maintenance And Care - Flex DD 2G 10.8-EC Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
DD 2G 10.8-EC / PD 2G 10.8-EC
 Insert battery into the charger as far as
stop.
The LED charge status flashes and the
battery is charged.
When the battery is fully charged, the
LED charge status is lit continuously.
 Remove the battery from the charger.
 Pull out the mains plug.
Fault messages
If the LED fault message lights up after the
battery is inserted into the charger, there is
an fault with the battery or charger.
The LED warning message is lit up
continuously:
– The battery is too hot or too cold.
The charging process starts when the
battery reaches the charging tempera-
ture (0°C...40°C).
The LED fault message flashes or none of
the two LEDs lights up:
– Remove battery from the charger.
Check contacts at charger and battery
for contamination and clean if necessary.
Reinsert battery. The battery is faulty
if the same display appears again.
Replace battery or have it checked in
a professional workshop.
– If this fault message is also displayed
with a different battery, then there is
a fault with the charger. Have the charger
checked by a professional workshop.
Tips for a long battery service life
CAUTION!
Never charge batteries at temperatures
below 0 °C or above 40 °C.
Do not charge batteries in environments
with high air humidity or ambient
temperature.
Do not cover batteries and the charger
during the charging process.
Pull out the charger mains plug at the end
of the charging process.
Battery and charger heat up during the
charging process. This is perfectly normal!
Lithium-ion batteries do not exhibit the
established "memory effect". Nevertheless, a
battery should be completely discharged
before charging and the charging process
should always be fully completed.
If batteries are not used for an extended
period of time, store them partially charged in
a cool place.

Maintenance and care

Cleaning
WARNING!
If metals are worked over a prolonged
period, electroconductive dust may become
deposited inside the housing.
Clean the power tool and ventilation slots at
regular intervals. Frequency of cleaning is
dependent on the material machined and
the duration of use.
 Regularly blow out the housing interior
and motor with dry compressed air. Keep
the power tool running while doing this.
Charger
WARNING!
Before performing any work, pull out
the mains plug. Do not use water or liquid
detergents.
 Remove dirt and dust from the housing
with a brush or a dry cloth.
Repairs
Repairs may be carried out by an authorised
customer service centre only.
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pd 2g 10.8-ec

Table of Contents