2.15.2 Securing a rack-mounted system into a rack

optional
The
p5-550Q rack-mounted model. No tools are required to install the p5-550, p5-550Q, or drawer
rails into the system rack.
The kit has a modular design that can be adapted to accommodate various rack depth
specifications. The drawer rails are equipped with thumb-releases on the sides, toward the
front of the server, that allow for easy slide out from its rack position for servicing.
Note: Always exercise standard safety precautions when installing or removing devices
from racks. By placing the rack-mounted system or expansion unit in the service position,
you can access the inside of the unit.

2.15.3 Serving a rack-mounted system into a rack

To place the rack-mounted system or expansion unit into the service position, follow these
steps:
1. If necessary, open the front rack door.
2. Remove the two thumbscrews (A) that secure the system or expansion unit (B) to the rack,
as shown in Figure 2-19.
Figure 2-19 Pull the p5-550 or p5-550Q to the service position
3. Release the rack latches (C) on both the left and right sides, as shown in the Figure 2-19.
4. Review the following notes, and then slowly pull the system or expansion unit out from the
rack until the rails are fully extended and locked.
– If the procedure you are performing requires you to unplug cables from the back of the
system or expansion unit, do so before you pull the unit out from the rack.
rack-mount drawer rail kit is a unique kit designed for use with the p5-550 or