7311 I/O Drawer Rio-2 Cabling - IBM System p5 550 Technical Overview And Introduction

Hide thumbs Also See for System p5 550:
Table of Contents

Advertisement

7311 Model D20 internal SCSI cabling
A 7311 Model D20 supports hot-swappable disks using two 6-pack disk bays for a total of 12
disks. Additionally, the SCSI cables (FC 4257) are used to connect a SCSI adapter (that can
have various features) in slot 7 to each of the 6-packs, or two SCSI adapters, one in slot 4 and
one in slot 7. See Figure 2-10 for a drawing of the SCSI cables internal routing.
Figure 2-10 7311 Model D20 internal SCSI cabling
Note: Any 6-pack and the related SCSI adapter can be assigned to a single partition. If
one SCSI adapter is connected to both 6-packs, both 6-packs can be assigned only to the
same partition.

2.8.3 7311 I/O drawer RIO-2 cabling

As described in 2.8, "External I/O subsystem" on page 43, you can connect up to four I/O
drawers in the same loop and up to eight I/O drawers to the p5-550 or p5-550Q system. Each
RIO-2 port can operate at 1 GHz in bidirectional mode and is capable of passing data in each
direction on each cycle of the port. Therefore, the maximum data rate is 4 GBps per I/O
drawer in double barrel mode.
There can be up to two RIO-2 loops in any p5-550 or p5-550Q system. These features
provide up to four remote I/O ports for attaching up to eight 7311 Model D20 I/O drawers to
the system for an aggregate data rate of 4 GBps.
Figure 2-11 on page 45 shows how you could connect logically height I/O drawers to one
p5-550 or p5-550Q system. Actual cables should be routed according to installation
instructions.
44
IBM System p5 550 and 550Q Technical Overview and Introduction
Connect the SCSI cable feature to the SCSI adapter
in rightmost slot (7) as shown below:
to 6-pack
backplanes
If a SCSI card is also placed in slot 4, wire as shown below:
SCSI cables FC 4257
to 6-pack
backplanes
SCSI cables FC 4257

Advertisement

Table of Contents
loading

This manual is also suitable for:

System p5 550q

Table of Contents