Enabling And Disabling Link Integrity - Compaq Netelligent 3024 User Manual

10base-t repeater
Table of Contents

Advertisement

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Collision/Mode 2
Ports 1-24

Enabling and Disabling Link Integrity

Each repeater port is set at the factory to enable link integrity. To change the
link integrity status for a port, perform the following steps:
1. Read through this procedure once before you change the link integrity
2. From the default mode, press the configuration button twice. The Mode
3. Press and hold down the button until the Mode 2 LED begins blinking
4. While the Mode 2 LED is blinking, press and hold down the button.
5. Press and release the button once again to store the selection. The LED
6. Repeat Steps 4 and 5 to disable additional ports.
7. Once all the changes are made, press and hold down the button until
LED
configuration.
2 LED displays a steady GREEN light.
GREEN. Then release the button.
(The LED blinks only for a few seconds before the repeater returns to
the default mode.) A YELLOW cursor starts to scroll through the Port
1-24 LEDs. Release the button when the cursor reaches the LED that
corresponds to the port you want to change. The LED blinks
YELLOW.
alternately blinks YELLOW and GREEN to indicate the repeater has
stored selection.
the Mode 2 LED blinks GREEN. The mode LED stops blinking after
several seconds
Table 5-4
Mode 2 Example
LED Color
GREEN
Link Integrity mode is active
OFF
Link integrity enabled
GREEN
Link integrity disabled
Netelligent 3024/3124 10Base-T Repeater User Guide
Description
5-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netelligent 3124

Table of Contents