Installation - FRIGOGLASS EASYREACH EXPRESS [R290] User Manual

Table of Contents

Advertisement

3.

Installation

The Easyreach Express packing consists of a wooden pallet, a full body carton box, a plastic bag and
four e.p.s. blocks for the protection of the unit. Unpack the unit and remove it from the pallet.
EASYREACH EXPRESS [R290] is equipped with HC refrigerant,
and has been tested and proven to be safe according to related
standards.
All necessary actions for safe usage & maintenance of this
appliance are described in this manual and need to be followed
carefully.
This appliance must be installed only by a suitably qualified
person.
Failure to comply with the instructions may result in high-energy
consumption, poor performance of the unit and void warranty.
Keep all ventilation openings in the appliance enclosure or in the
built-in structure clear of obstruction.
Do not use mechanical devices or other means to accelerate the
defrosting process, other than those recommended by the
manufacturer.
Do not damage the refrigerant circuit.
Do not use electrical appliances inside the food storage
compartments of the appliance, unless recommended by the
manufacturer.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service provider or similarly qualified persons
in order to avoid a hazard.
After unpacking, check the cabinet for any damage caused during
transportation. In the event of damage, please contact the forwarding
company.
Allow the merchandiser to stand upright for at least 1 hour prior to
connecting to the mains supply. This gives the oil time to run back to the
compressor after transit and installation.
ENG
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Easyreach express hc

Table of Contents