FAULT
The unit does not cool
enough or at all. The
products are warm.
The unit does not cool
enough or at all. The
products are warm.
The unit does not cool
enough or at all. The
products are warm.
The unit sometimes
makes noise.
There is water on the
floor.
The lights don't work.
The lights don't work.
POSSIBLE REASONS
The unit is loaded in such a way
that the air-circulation in the
interior is getting blocked.
The air-circulation grille at the
lower front of the unit is blocked.
It is more than 6 months since the
last cleaning of the condenser.
No air is circulating in the cold
chamber.
No air is circulating in the
condenser area at all times (note:
condenser fan operates only when
compressor runs.)
Leakage on the cooling system.
There is dirt blocking the inlet of
the evaporator.
For open front units, a powerful
mechanism is needed and
consequently the unit will produce
a certain amount of noise.
Intense metallic noise.
The drainage hose for condensate
water is out of the tray.
There is a leakage in the tray.
Excessive humid environment.
The light switch at the top back
side of the unit is switched off
(version without the Night Curtain).
The night bind is closed (versions
with a night curtain installed).
The fluorescent tubes, their
starters or ballasts are out of order.
HANDLING
Remove any products that are
placed on the suction grill next to
the front glass.
Remove any items blocking the
grille.
Clean the condenser (This
operation should be performed
by a qualified technician).
Possible fan motor failure.
Replace motor (This type of
repair should be performed by a
qualified technician).
Possible fan motor failure.
Replace motor (This type of
repair should be performed by a
qualified technician).
Repair leakage (This type of
repair should be performed by a
qualified technician).
Clean the evaporator(This
operation should be performed
by a qualified technician).
Contact the service provider.
Contact the service provider.
Contact the service provider.
Certain days with excessive
levels of humidity, overflow of
the tray could occur.
Turn on the light switch.
Retract the night curtain.
Contact the service provider.