Receiver.operations; Initial.settings; Receiver.setup - 3M Dynatel 2220M Operator's Manual

Advanced pipe/cable locator
Hide thumbs Also See for Dynatel 2220M:
Table of Contents

Advertisement

Receiver Operations
Initial Settings
From.the.manufacturing.facility,.the.receiver.is.configured.as.follows:.
Line Locate Frequencies
8 kHz
8 kHz
Power
Radio
CATV
CPS
Sonde Locate Frequencies
5 Hz
640 Hz
33 kHz
Units
Power Frequency
Contrast
Depth Measurement
The.setup.function.will.allow.you.to.enable.or.disable.additional.locating.and.
sonde.frequencies..
Receiver Setup
Any.of.the.available.frequencies.of.the.3M
Locator.2220M.can.be.activated.or.deactivated..When.a.frequency.is.activated,.
a.check.mark.will.appear.beside.the.frequency.in.the.middle.of.the.setup.screen..
All.frequencies.that.are.activated.in.the.setup.menu,.will.be.available.in.the.
locate.screens.
When.the.Setup.key.is.pressed,.the.receiver.will.cycle.through.the.following.
screens..
Select.the.left/right.arrow.keys.(← →).to.cycle.through.the.setup.screens.
Contrast Adjust
Press.the.up.or.down.arrows.( .or. ).to.
adjust.the.screen.contrast.
Selection
Always Enabled
Always Enabled
Always Enabled
Enable/Disable
Enable/Disable
Enable/Disable
Enable/Disable
Enable/Disable
Enable/Disable
inch or cm
50 Hz or 60 Hz
Up or Down
Live or One-Shot
.Dynatel
8
Default
Enabled
Enabled
Enabled
Disabled
Disabled
Disabled
Enabled
Disabled
Enabled
Inch
60 Hz
Middle
One-Shot
.Advanced.Pipe/Cable.