13.3

Adjusting the Lift Scale

The lift scale can only be adjusted with connected and switched on stud
welding unit.
‹ Observe the safety instructions in the operating manual of the connected
stud welding unit.
‹ Refer here to the operating manual of your stud welding unit.
1
‹ Screw off the cap at the rear.
‹ Now screw in the lift up to the stop by turning clockwise.
‹ Now screw out the lift step by step by turning counter-clockwise.
‹ Push the welding gun trigger and check if lift is triggered.
‹ Repeat this procedure until a lifting motion at the chuck is visible.
‹ Lock this position with an allen key (size 8).
‹ Loosen both slotted screws.
‹ Adjust the scale wheel by turning and setting the zero position onto the marking.
‹ Then tighten the slotted screws.
‹ Screw on the cap again.
Now the scaling 'Lift' is adjusted.
©HBS Bolzenschweiss-Systeme GmbH & Co. KG
All rights reserved – Reprinting, in whole or in part, only with the approval of the manufacturer
3
4
2
5
13 Maintenance and Care
1 - Cap
2 - Marking
3 - Scale wheel
4 - Slotted screw
5 - Allen key size 8