Dometic Oceanair Skysol Powered Roofblind Installation And Operating Manual page 22

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Installation
Key to wiring diagrams
Pos.
1
2
3
4
5
bk
rd
gy
wh
I
NOTE
• Accessories are available using the separate order form.
• Observe the applicable documents for the controls and the operating ele-
ments.
7.2
Frame fitting (pre-assembled version)
7.2.1
Frame fitting
A
NOTICE! Risk of damage
• Use packing material where required (fig. 3, page 4). The side tracks must
be perpendicular to the head rail.
• Use screws and plugs suitable for the wall construction to fix the frame to
the recess. Pre-drill at the marked points.The heads of screws may be no
larger than 6.0 mm in diameter.
• Ensure not to drill through the wall.
• Ensure not to damage the channel in the side tracks.
• Ensure not to leave screws or other debris inside the side tracks as this can
jam the shoes in the tracks and cause the blind to fail.
Proceed as shown (fig. 4, page 4):
1. Align the blind with the window cut-out and mark where the holes are to be
drilled for the frame.
2. Ensure the frame is square within the recess by using a measuring device.
Measure the outside corner of the frame to the opposite outside corner and
repeat for the other two corners. These measurement should be within
3 mm of each other.
3. Fix the frame with the screws to the ceiling (2.).
22
Description
Fused 12 Vg/24 Vg power supply (fuse rating 2 A for 24 Vg, 1 A for
12 Vg)
Head rail
Head rail motor options
External receiver
Customer supplied DPDTswitch (double pole, double throw), center off,
latching or momentary, 12/24 Vg, 3 A)
Black
Red
Gray
White
Skysol Powered Roofblind
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

9600023490

Table of Contents