Troubleshooting - Vacmaster VQ1220PF Original Instructions Manual

20l 1250w
Hide thumbs Also See for VQ1220PF:
Table of Contents

Advertisement

WARNING:

TROUBLESHOOTING.

Cleaning Performance
Vacmaster vacuum cleaners are tested for endurance. If your motor is operating, then the most
likely cause for a loss in suction is a blockage or an opening in the vacuum.
To maintain a high cleaning performance from your machine, it is important to replace or clean
reusable cloth filters as necessary. A performance drop with clean filters can only be caused by a
blockage in the tools or the hose.
PROBLEM
The appliance does
not work.
Dust is escaping from
the motor cover.
Low suction power
and high operating
noise / vibrations.
TROUBLESHOOTING
TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
POSSIBLE CAUSE
No power.
Functional fault in the power
cord, switch, or motor.
The reusable cloth filter is
missing or damaged.
Misuse the reusable cloth filter
when wet vacuuming, causing
the damage of reusable cloth
filter.
Misuse the foam filter when
dry vacuuming.
Suction nozzle, hose, or tank
inlet is blocked.
Reusable cloth filter is
blocked.
Float valve has closed.
Check the power supply and fuse.
Have the damaged part checked by
qualified personnel or contact the after
sales helpline.
Put in a reusable cloth filter or replace
it.
Replace the damaged reusable
cloth filter with a new one when dry
vacuuming.
Replace the foam filter with the
reusable cloth filter.
Check the suction nozzle, hose, and
tank inlet for obstructions.
Remove the reusable cloth filter and
clean.
Empty the container of any liquid
waste and ensure the float value
located underneath the filter is able to
move freely.
13
SOLUTION

Advertisement

Table of Contents
loading

Table of Contents