Problem
Insulation exiting hose is
dribbling out.
Blower does not operate.
Agitator does not operate.
Circuit breakers need resetting
often.
Machine makes a banging noise
when agitator is operating.
T: 303-833-6644
Original Language - English
Likely Cause
Heavy insulation material.
Kink in hose.
Airlock seal is worn.
Worn brushes in blower motor.
Insulation is jamming the
agitator.
Insulation blockage in airlock
exit tube.
Agitator or airlock bearing may
need replacement.
Low voltage or low amperage.
Extension cord gauge is too
small.
Chain is not aligned with
sprockets.
Chain is loose.
Chain is not aligned with
sprockets.
Cyclone Instruction Manual
Remedy
Push slide gate in 1-2 holes.
Straighten hose.
Inspect airlock seals for cuts
and wear. Have a qualified
technician replace airlock seals.
Have a qualified technician
replace blower brushes or
replace blower motor.
Disconnect electrical power.
Remove insulation material
from hopper. Remove the
obstruction.
Disconnect electrical power.
Remove hose from the machine
outlet. Locate blockage and
remove.
Have bearing replaced by a
qualified technician.
System requires 115V / 20amp
or 230V / 10amp.
Use a 12/3 extension cord with
115V, or a 16A/250V 1.0mm2
extension cord with 230V.
Disconnect electrical power.
Have a qualified technician
realign chain and sprockets.
Disconnect electrical power.
Have a qualified technician
adjust chain tensioner.
Adjust chain tensioner.
Disconnect electrical power.
Have a qualified technician
realign chain and sprockets.