Section 5.1
Power Supply Specifications
Power Supply Type
12-24 VDC
24 VDC
48 VDC
d
HI (125/250 VDC)
d
HI (110/230 VAC)
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
This is the same power supply for both AC and DC.
Power Supply Specifications
Input Range
Minimum
Maximum
10 VDC
18 VDC
36 VDC
88 VDC
300 VDC
85 VAC
265 VAC
Internal Fuse Rating
36 VDC
6.3 A(F)
36 VDC
5 A(F)
59 VDC
3.15 A(T)
3.15 A(T)
3.15 A(T)
Chapter 5
Technical Specifications
Maximum Power
ab
c
Consumption
15 W
19