Test
IEC 61000-4-17
IEC 60255-5
IEEE 1613 (C37.90.x) EMC Immunity Type Tests
NOTE
The RUGGEDCOM RS8000H meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
IEEE Test
IEEE 1613 Clause
C37.90.3
C37.90.2
C37.90.1
C37.90
28
Description
Ripple on DC Power Supply
Dielectric Strength
HV Impulse
9
ESD
8
Radiated RFI
7
Fast Transient
Oscillatory
6
HV Impulse
Dielectric
Strength
DC Power ports
30 V Continuous, 300 V for 1 s
DC Power ports
Signal ports
2 kVAC  (Fail-Safe Relay output)
DC Power ports
AC Power ports
Signal ports
5 kV  (Fail-Safe Relay Output)
DC Power ports
AC Power ports
Description
Enclosure Contact
Enclosure Air
Enclosure ports
Signal ports
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
RUGGEDCOM RS8000H
Installation Guide
Test Levels
Severity Levels
10%
1.5 kVDC
2 kVDC
5 kV
5 kV
Test Levels
±8 kV
±15 kV
35 V/m
±4 kV @ 2.5 kHz
±4 kV
±4 kV
±4 kV
2.5 kV common mode @ 1MHz
2.5 kV common and
differential mode @ 1MHz
2.5 kV common and
differential mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
5 kV
2 kVAC (Failsafe Relay)
1.5 kVDC
2 kVAC
EMC and Environmental Type Tests
4