Chamberlain TPD10-05 Mechanical And Electrical Installation Manual page 12

Table of Contents

Advertisement

JUMPERS
1 / 2 Motor
1 or 2 motors are connected to the control board.
FREE:
both motors connected
LINKED: only one motor connected
STOP / 8.2 KOhms
Defines if connector STOP / 8.2 KOhms is used for an emergency
stop switch or for a safety edge. The emergency stop switch stops
any movement of the system immediately. The safety edge causes
the wings to reverse for one second.
FREE:
Factory setting is for 8.2 KOhms. In this case safety edge
must be installed or a 8.2 KOhms resistor must be
connected.
LINKED: used for emergency stop switch, in this case the pre-
installed resistor has to be removed from terminals and
replaced by a suitable switch or terminals have to be
bridged.
Open / Ped
Defines if key switch operates only one wing (Master) or both wings
FREE:
only one wing (Master)
LINKED: both wings
1/2 MOTOR
STOP/8.2KΩ
OPEN / PED
JP1
JP2

Advertisement