ΗΕΑςΨ ∆ΥΤΨ, ΗΑΡΣΗ ΕΝςΙΡΟΝΜΕΝΤ ΣΛΙ∆Ε ΓΑΤΕ ΟΠΕΡΑΤΟΡ 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) MODELS SL585 AND SL595 ARE FOR VEHICULAR Installation Date __________________ PASSAGE GATES ONLY AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE...
Page 2
Electrical Boxes ........31 Safety Gate Brochure Repair Parts - Model SL585 ......32 Gate Bracket Illustrated Parts - Model SL585 .
Page 3
Ο Π Ε Ρ Α Τ Ο Ρ ∆ Ι Μ Ε Ν Σ Ι Ο Ν Σ Α Ν ∆ Η Ο Ρ Σ Ε Π Ο Ω Ε Ρ Χ Η Α Ρ Τ MODEL SL585 • 1/2 HP Motor 28.9"...
Page 4
Υ Λ 3 2 5 Μ Ο ∆ Ε Λ Χ Λ Α Σ Σ Ι Φ Ι Χ Α Τ Ι Ο Ν Σ CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
Page 5
Σ Α Φ Ε Τ Ψ Ι Ν Σ Τ Α Λ Λ Α Τ Ι Ο Ν Ι Ν Φ Ο Ρ Μ Α Τ Ι Ο Ν 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
Page 7
ΣΑΦΕΤΨ ΠΡΕΧΑΥΤΙΟΝΣ ΦΟΡ ΟΠΕΝ ΡΟΛΛΕΡ ΓΑΤΕΣ Gate Edge on Fence Gate Edge on Post for Open Direction Gate Edge On Rear of Gate for Leading Edge of Gate Open Direction For Close Direction • Injuries occur when people get their hands or feet caught between the top or bottom of the gate and the gate roller.
Page 8
Ω Ι Ρ Ι Ν Γ To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install any wiring or attempt to run the operator without consulting the wiring diagram. We recommend that • ANY maintenance to the operator or in the area near the you Install an optional reversing edge BEFORE proceeding with operator MUST not be performed until disconnecting the the control station installation.
Page 9
Ι Ν Σ Τ Α Λ Λ Α Τ Ι Ο Ν ΠΑ∆ ΜΟΥΝΤΙΝΓ (ΣΛ585 ΟΝΛΨ) Figure 1 RETRO-FIT INSTALLATION The operator is shipped from the factory with the lower mounting angles configured out (Figure 1). If you have pad constrictions, either angle can be unbolted and reversed to ‘angle in’.
Page 10
14" (35.6 cm) Min. Ground Level 3" (7.6 cm) U-bolt (4 required) Depth As Required By Local Codes or Below Frost Line SL585 ONLY Power and Control Wiring Should Be Run In Separate Conduit Drive and Idler Sprocket Toward Figure 3...
Page 11
ΙΝΣΤΑΛΛ ΓΑΤΕ ΒΡΑΧΚΕΤ ΑΝ∆ ∆ΡΙςΕ ΧΗΑΙΝ Figure 1 “Outside” To prevent damage to the operator or gate, DO NOT drive the Gate limit (nuts) actuators on the shaft past their normal positions. “Inside” 1. Mount gate brackets to the vertical front and rear posts of the gate (Figure 1).
Page 12
If phased incorrectly, the gate operator will run reversed. To correct this situation, shut off power at main power source and at the operators electrical disconnect switch. Then reverse any two of the three power leads. ΜΑΝΥΑΛ ∆ΙΣΧΟΝΝΕΧΤ MODEL SL585 MODEL SL595 DISENGAGEMENT: Rotate disconnect handle 90˚ to...
Page 13
Α ∆ ϑ Υ Σ Τ Μ Ε Ν Τ ΛΙΜΙΤ ΣΩΙΤΧΗ Α∆ϑΥΣΤΜΕΝΤ NOTE: Make sure the limit nuts are positioned between the limit To reduce the risk of SEVERE INJURY or DEATH: switch actuators before proceeding with adjustments. • Disconnect power BEFORE performing ANY adjustments. 1.
Page 14
ΙΝΣΤΑΛΛ ςΕΝΤ ΠΛΥΓ 1. Remove fill plug from gear box. 2. Install vented plug provided with the hardware box. Fill Plug 3. Remove relief valve from the new vented plug. Drain Plug ΥΛ325 ΕΝΤΡΑΠΜΕΝΤ ΠΡΟΤΕΧΤΙΟΝ PRIMARY ENTRAPMENT PROTECTION ADJUSTMENTS Force Control Force Control GL Control Board Set the force control pot such that the unit will complete a full...
Page 15
ΥΛ325 ΕΝΤΡΑΠΜΕΝΤ ΠΡΟΤΕΧΤΙΟΝ (ΧΟΝΤΙΝΥΕ∆) EDGE/PHOTO OPEN EDGE/PHOTO CLOSE This switch (S2-4) selects edge or photo sensor for the gate This switch (S2-3) selects edge or photo sensor for the gate closing protection input. opening protection input. (Factory Default) PHOTO OPEN PHOTO CLOSE Open Photo Eye (Pause): When the Close Photo Eye (Reverse): When...
Page 16
ΠΡΟΓΡΑΜ ΣΕΤΤΙΝΓΣ (∆ΙΠ ΣΩΙΤΧΗ Σ1) NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode switch must be set to the off position. TIMER TO CLOSE ENABLE TIMER TO CLOSE This switch enables the auto close timer. The timer to close feature works in conjunction with the potentiometer located on Max = 180 sec the board.
Page 17
ΧΟΝΤΡΟΛ ΧΟΝΝΕΧΤΙΟΝ ∆ΙΑΓΡΑΜΣ Accessory Terminal Block Accessory Terminal Block 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 24Vac Accessory Power May Be Found On These Terminals 24 Vac Soft Open Input (N.O) Control Board...
Page 18
ΑΧΧΕΣΣΟΡΨ ΩΙΡΙΝΓ All inputs are normally open and momentary, except the stop (N.C.). The following instructions are based upon UL325, and include recommendations for significant increase in safety. We strongly recommend that you follow the UL guidelines presented throughout the manual. Refer to instructions shipped with optional control devices for mounting, wiring, programming and adjustment.
Page 19
ΑΧΧΕΣΣΟΡΨ ΩΙΡΙΝΓ (ΧΟΝΤΙΝΥΕ∆) Terminals 7 & 5 (Com) - Hard Open Override Control Input Hard Open Override Control Input These terminals are intended for use only with the open control 3 4 5 6 7 8 of a 3-button station that is installed within line of sight of the gate.
Page 20
3 on the BG770 barrier gates terminal strip. b) Use a loop system to close the barrier gate after the vehicle 6. Attach a wire from terminal 5 of the SL585/595 accessory has passed through the SAM system.
Ο Π Ε Ρ Α Τ Ι Ο Ν Α Ν ∆ Μ Α Ι Ν Τ Ε Ν Α Ν Χ Ε IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL INSTRUCTIONS. 5.
Page 22
The brake is spring-applied whenever the motor is not running. Anytime the motor is running, the electric solenoid physically releases the brake. A solenoid brake is standard on SL585/595 operators. The brake Solenoid is adjusted at the factory and should not need additional Release adjustment for the the life of the friction pad.
Page 23
ΧΟΝΤΡΟΛ ΒΟΑΡ∆ ΠΡΟΓΡΑΜΜΙΝΓ ΑΝ∆ ΦΕΑΤΥΡΕΣ (ΧΟΝΤΙΝΥΕ∆) LED Code Diagnostic Meaning Cleared By FORCE CONTROL Flashed Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without Normal operation applying an unreasonable amount of force.
Page 24
Τ Ρ Ο Υ Β Λ Ε Σ Η Ο Ο Τ Ι Ν Γ FAULT POSSIBLE CAUSE OPERATOR FAILS TO RUN 1) Improper wired stop control Check the green LED (D17) on control board. If the green LED is off, ➤...
Page 25
Τ Ρ Ο Υ Β Λ Ε Σ Η Ο Ο Τ Ι Ν Γ FAULT POSSIBLE CAUSE MASTER OR SECOND 1) Failure to cycle power after setup The power to each unit must be cycled in order to initiate proper ➤...
Page 26
TO REVERSE MOTOR (SEE NOTE 1) DIRECTION INTERCHANGE FUSE (YE) PURPLE & GRAY WIRES INTERNAL MOTOR 3.15A ON MODEL SL585 WIRING (BL) (TB 2) OR THE RED & GREEN WIRES 1 - BLUE ON MODEL SL595 2 - WHITE 3 - ORANGE...
Page 27
Σ Ι Ν Γ Λ Ε Π Η Α Σ Ε Ω Ι Ρ Ι Ν Γ ∆ Ι Α Γ Ρ Α Μ W A R N I N G To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. BLACK (SL595 ORANGE) SEE NOTE 3 CONTACTOR...
Page 29
Τ Η Ρ Ε Ε Π Η Α Σ Ε Ω Ι Ρ Ι Ν Γ ∆ Ι Α Γ Ρ Α Μ To protect against fire and electrocution: BLACK (SL595 ORANGE) AUXILIARY RELAY • DISCONNECT power BEFORE installing or servicing operator. EXTERNAL OVERLOAD SEE NOTE 5 SEE NOTE 3...
Page 38
TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing.
Page 39
DEK CANADA INC 1928 ST-REGIS BLVD. DORVAL, QC H9P 1H6 TEL: 514-685-5800 TOLL-FREE: 1-800-361-3198 F F AX: 514-685-5804 www.dekcanada.com...