4.4 LIN-300 Series Modules - General specifications
Operation
Matching sensor
•
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
LIN-304S-6I-0,3/4,3
Measuring range
•
Output
•
Sensitivity
•
Accuracy
•
Repeatability
•
Interchangeability
•
Frequency response
•
Output load
•
Temperature drift
•
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
LIN-306S-6I-0,3/6,3
Measuring range
•
Output
•
Sensitivity
•
Accuracy
•
Repeatability
•
Interchangeability
•
Frequency response
•
Output load
•
Temperature drift
•
Power requirement
Voltage
•
Consumption
•
Protection
•
Connection
Cable from sensor
•
Power & output cable
•
Environmental
Temperature:
•
- Operation
- Storage
Humidity
•
Physical characteristics
Die cast aluminium compact casing body
•
Dimensions:
A - Height
B - Width
C - Length
Copyright © VibroSystM Inc., 2010
PCS-200ESB
0.3 to 4.3 mm
[12 to 169 mils]
4 to 20 mA
[101.9 μA /mil]
4 mA/mm
< 3% of reading at mid-range
< 0.3 % of reading at mid-range
< 3 % of reading at mid-range
DC to 1 kHz (-3dB)
500 Ω max.
°
< 500 ppm/
C
0.3 to 6.3 mm
[12 to 248 mils]
4 to 20 mA
[67.8 μA /mil]
2.667 mA/mm
< 3% of reading at mid-range
< 0.3 % of reading at mid-range
< 3 % of reading at mid-range
DC to 1 kHz (-3dB)
500 Ω max.
< 500 ppm/
°
C
+24V
+/- 15%
DC
90 mA (+24V
)
DC
auto-reset fuse
SMA socket and grounding screw
M12 socket
0
°
to 55
°
C
[32
°
to 130
°
°
°
0
to 85
C
[32
to 185
Up to 95%, non condensing
44.5mm
[1.75 in.]
82.5mm
[3.25 in.]
139.5mm
[5.5 in.]
LIN-304S and LIN-306S Specifications_Rev. 1
°
F]
°
F]
39