2.3 General specifications of the PCS-200ESB sensor

Operation
Type of measurement
Linear measuring range
Frequency response
Accuracy
Repeatability
Interchangeability
Environmental
Temperature range
Humidity
Connection
Integral Cable
- Type
- Length
- Connector
- Cable Armor
Dimensions
Probe overall dimensions
- Diameter
- Length
- Tip
Thread
Ø 15.87 mm
0.625 in.
Probe Tip
Figure 12 : PCS-200ESB dimensions
16
PCS-200ESB Universal Proximity Sensor_Installation_Rev. 1
non-contact proximity, capacitive technology
varies depending on Linearization Module used
limited by the Linearization Module used
< 2.5 % of reading at mid-range
< 0.3 % of reading at mid-range
< 2.5 % of reading at mid-range
°
°
-50
to 200
C [-58
Up to 95%, non-condensing
Triaxial
5.5 m [18 ft.] minimum
Male SMA with ground lug (standard),
or male BNC with ground lug (legacy)
Integral flexible stainless steel metallic conduit,
diam. 5.6 mm [0.220 in.], on 5 m [16.4 ft.] standard
19 mm
[0.75 in.]
142.24 mm
[5.60 in.]
15.84 mm
[0.625 in.]
3/4-16 UNF
3/4"-16 UNF
Integral Cable (Minimum Length 5.5 m / 18 ft )
Including 50 cm / 20 in. Flexible Cable Armor
130.17 mm / 5.125 in .
142.24 mm / 5.600 in .
°
°
to 392
F]
Copyright © VibroSystM Inc., 2010