TRANSIT ENTRY | INSTALLATION GUIDE

Connections

3
CONNECTIONS
3.1

CABLE CONNECTIONS

Cable connections to the TRANSIT Entry are made using the EMC cable glands.
Shielded cable shall be used for all connections including the DC-supply
connection.
Assembly instructions:
Push the cap nut (1),
1
seal insert (2) and
gland contact socket
(3) onto the cable.
Cut back the outer
2
sheath to desired
length.
Bend over the screen
3
braiding (4) over the
gland contact socket
and cut back the
screen braiding as
shown in Figure 6.
Screw the cap nut onto
4
reader part until the seal
insert is pushed out of the
gland. See Figure 7.
Correct mounting and tightening the EMC cable glands is essential for water
protection.
See appendix Error! Reference source not found.A for detailed information on the
cable glands.
1
2
3
Figure 6: Cable shield
Figure 7: Gland tightening
4