Advertisement

 
Instruction Manual
VP1007-B
Installation manual
Version 01.000 / November 2020 / EN
Original instructions
Livestock Management

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VP1007-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Nedap VP1007-B

  • Page 1   Instruction Manual VP1007-B Installation manual Version 01.000 / November 2020 / EN Original instructions Livestock Management...
  • Page 2 Copyright © Nedap N.V. All rights reserved. The information in this document is subject to change without notice, it is not to be reproduced in any way, in whole or in part, without the written consent of Nedap N.V. All trademarks referenced belong to their respective owners.
  • Page 3   VP1007-B VP1007-B / Installation manual Livestock Management Version 01.000 / November 2020 / EN...
  • Page 4: Table Of Contents

    Glossary ..................... 20 Technical specifications ..............21 Handling instructions ................22 Compliance ..................23 Appendix .................... 25 11.1 VP1007-B reader LED indicators ................25 11.2 VP1007-B reader menu overview ................26 11.3 Wiring color coding ...................... 28 VP1007-B / Installation manual Livestock Management Version 01.000 / November 2020 / EN...
  • Page 5: Safety

    Always wear proper protection when installing and maintaining the VP1007-B. Caution Use the VP1007-B only with a suitable power supply. The power supply or power adapter must comply with local regulations for a SELV, limited power (NEC class2, ps2) output (e.g. Nedap VP2001-B or Nedap power adapter (P/N 9223126)).
  • Page 6 Caution Make sure all cables are properly concealed, and form no danger for stumbling. Caution Take into account the high concentrations of ammonia when installing and maintaining the VP1007-B in pig barns. Animal welfare and safety The automated actions of the Nedap Livestock Management systems do never discharge the installer and the user of the system from his/her responsibility to assure and to take care of the well-being of the animals.
  • Page 7: Vp1007-B Introduction

    24-hour period. For more information see the menu overview of the V-pack in the Appendix. To check if the VP1007 is a B version, a "b" will appear on the display shortly after the VP1007-B is booted.
  • Page 8: Installation

    Caution Nedap power supplies must be connected to a power socket with protective earth (PE). Always use a 3-pole connector with a PE contact. If there is no PE available, create a PE next to the power socket to be used for each power supply. The properties of a correct PE depend on local circumstances and legislation.
  • Page 9: Tools Requirements

    Mount the VP1007-B in a dust and splash proof housing, preferably a Nedap V-box: If the VP1007-B is installed as a part of a complete Nedap system, use the installation manual of this system. The installation manual can be obtained from your dealer or on our Business portal: http:// www.nedap.com/livestockmanagement-portal.
  • Page 10 Velos CAN cable Wiring Wire color Power +25 Vdc Power – Black Blue High Blue/white Orange HF synchronization Orange/white HF synchronization Blank Shield communication wires Blank Shield synchronization wires VP1007-B / Installation manual Livestock Management Version 01.000 / November 2020 / EN...
  • Page 11: Wiring Diagram Vp1007-B

    Wiring colors: see Wiring color coding (page 28)  4. Feed motor 1. Install all wiring according to the VP1007-B wiring diagram. An example of a VP1007-B wiring diagram is shown in Figure 1 (page If the VP1007-B is part of a complete Nedap system, use the installation manual of this system. The installation manual can be obtained from your dealer or on our Business portal: http://www.nedap.com/...
  • Page 12 – Use a 2-conductor cable to connect the SYNC connectors of two or more VP1007-B transceivers together. The cable type is not critical, a twin lead or coaxial cable can be used. Also the connection is not sensitive for polarization (+ and - are interchangeable).
  • Page 13: Configuration

    When the logic address is not a unique number, the logic address will blink in the display. b. Go to parameter Ad > SA to set the logic address of the VP1007-B reader to a unique number when multiple V-packs are connected to the same VPU.
  • Page 14: Check For Firmware Updates

    The VPUs and V-packs are never updated automatically by the VPU. Update via the VPU When the VPU or V-pack is connected with a computer, the firmware can be updated using the Nedap Velos software: 1. In Velos, go to Maintenance > Devices - V-packs.
  • Page 15: Commissioning

    Encountered issues and problems must be solved first. 5.1 Testing inputs and outputs The inputs and outputs of the VP1007-B can be tested with three tests: 1. Input/output test for Nedap feed motors. 2. Output test to check connected equipment like lights, valves or relays.
  • Page 16: Antenna Tuning

    The on and off setting must show a unique value (0 or 1). When the VP1007-B is part of a complete Nedap system, the meaning of the input values (open or closed) depends on the settings of the behavior component of the Nedap system.
  • Page 17 Squelch: The traditional squelch circuit is an audio switch controlled by the radio signal level using a fixed or manually adjustable threshold (level). When the received signal strength falls below this, the receiver is muted. When the VP1007-B reads the tag with an RSSI level below this threshold, the tag will not be read. Figure 2: Antenna squelch (AS) diagram  1.
  • Page 18: Identification Tests

    26). Tag identification When a tag is detected by the antenna of the VP1007-B, the green TUNING/ID LED will automatically blink. The identification (id) test can be used to identify the tag number. 1. When the green TUNING/ID LED blinks, go to It > id on the display.
  • Page 19 FDX/HDX signal strength indication The signal strength received by the reader of the VP1007-B can be tested. The FDX (dF) and HDX (dH) signals are tested separately. 1. FDX test: a. Go to HF > AS > dF on the display.
  • Page 20: Troubleshooting

    6 Troubleshooting Errors and malfunctioning of the VP1007-B are indicated by the indicator LEDs or codes on the display. Indicator LED Indicator LEDs are normally green (except the blue Status LED) or switched off. A red or orange indicator LED usually means there is something not functioning correctly.
  • Page 21 filters have not been installed. If there is interference, try to locate the source: 1. Follow the instructions in the manual "Optimizing animal identification", which can be obtained from your dealer or on our Business portal: http://www.nedap.com/livestockmanagement-portal. VP1007-B / Installation manual Livestock Management...
  • Page 22: Glossary

    The traditional squelch circuit is an audio switch controlled by the radio signal level using a fixed or manually adjustable threshold (level). When the received signal strength falls below this, the receiver is muted. When the VP1007-B reads the tag with an RSSI level below this threshold, the tag will not be read.
  • Page 23: Technical Specifications

    Approx. 360 g (12.7 oz.) Power supply The power supply or power adapter must comply with local regulations for a SELV, limited power (NEC class2, ps2) output (e.g. Nedap VP2001 or Nedap power adapter part no. 9223126). Power supply input voltage 25 VDC, ±...
  • Page 24: Handling Instructions

    In so doing, you will help to conserve natural resources and improve standards of environmental protection in treatment and disposal of electrical waste (Waste Electrical and Electronic Equipment Directive WEEE 2012/19/EU). VP1007-B / Installation manual Livestock Management Version 01.000 / November 2020 / EN...
  • Page 25: Compliance

    Connect the equipment into an outlet on a circuit different from that to which the receiver. • Consult the dealer or an experienced radio/TV technician for help. VP1007-B / Installation manual Livestock Management Version 01.000 / November 2020 / EN...
  • Page 26 B est conforme à la norme Canadienne ICES-003. Antennas This device may be used with the following Nedap antennas: VP6011, VP6012, VP6030, VP6040, VP6041, VP6042 and VP6050. Antennas VP6041 and VP6042 are identical. However, model VP6041 is adjusted for environments with lots of steel for short distances. The VP6042 is adjusted for longer distances (1 m) recognition.
  • Page 27: Appendix

    11 Appendix 11.1 VP1007-B reader LED indicators Color   Mode State POWER Green Power on Blank Power off STATUS Blue Slow blinking Working and linked to Behavior Component 1 long flash Working and not linked to Behavior Component Fast blinking...
  • Page 28: Vp1007-B Reader Menu Overview

    Red blinking Antenna 2 not connected or low antenna signal 11.2 VP1007-B reader menu overview Use the button to access the menu and to display or change the settings: 1. Push the button briefly to go through the menu options.
  • Page 29 Display HDX RSSI       Identification test       Antenna options       Notch filter (VP1007-B only)       Notch filter off       Notch filter on       Notch filter temporarily on (for 24 hours))  ...
  • Page 30: Wiring Color Coding

    Enter value 99 to set all settings on the V-pack to factory defaults. 11.3 Wiring color coding Table 1: Wiring colors Color code Wire color Black Blue Brown Green Gray Orange Pink VP1007-B / Installation manual Livestock Management Version 01.000 / November 2020 / EN...
  • Page 31 Color code Wire color Violet White Yellow BK-WH Black-White BL-WH Blue-White BN-WH Brown-White GN-WH Green-White GY-PK Gray-Pink OR-WH Orange-White RD-BL Red-Blue YW-GN Yellow-Green YW-WH Yellow-White VP1007-B / Installation manual Livestock Management Version 01.000 / November 2020 / EN...