• All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes.
Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming
zones).
• Transmitter inputs entered as:
"RF" (Supervised RF) Type send periodic check-in signals, as well as fault, restore and low battery
signals. The transmitter must remain within the receiver's range.
"UR" (Unsupervised RF) Type send all the signals that the "RF" Type does, but the control does
not supervise the check-in signals. The transmitter may, therefore, be carried off-premises.
"BR" (Unsupervised Button RF) Type only send fault signals. Restore or check-in signals are not
sent, but low battery signals are sent when a button is pressed. The transmitter may be carried off-
premises.
5 8 0 1
LEARN AS "UR" OR "RF"
YOU MUST
LEARN THIS
BUTTON
LOOP 4
5 8 0 4
LEARN
AS "BR"
INPUT
(LOOP)
2
(REED)
LOOP 1
(TERMINALS)
5 8 1 6
LEARN AS "RF"
www.PDF-Zoo.com
5800 Series Transmitter Input Loop Identification
INPUT
(LOOP)
3
2
1
4
(ALWAYS USE)
5 8 0 2 M N
LEARN AS "UR" OR "RF"
LOOP 3
LOOP 2
LOOP 1
5808
LEARN AS "RF"
INPUT
(LOOP)
2
(REED)
LOOP 1
(TERMINALS)
ALTERNATE
5 8 1 6 M N
POSITION
LEARN AS "RF"
FOR LOOP2
firealarmresources.com
INPUT
(LOOP)
(PRIMARY)
INPUT
(LOOP)
1
(AUX. CENTER)
(AUX. RIGHT)
5 8 1 7
LEARN AS "RF"
INPUT
(DIP SWITCHES)
(LOOP)
2
(REED)
INPUT
(LOOP)
1
SET HOUSE ID
LOOP 3
(KEYPAD PROGRAMMABLE)
(TERMINALS)
5 8 1 9 S ( W H S & B R S )
LEARN AS "RF"
5 8 5 0 ( G B D )
LEARN AS "RF"
– 9 –
INPUT
(LOOP)
2
1
(REED)
2
LOOP 1
(TERMINALS)
3
LOOP 3
5 8 1 9
(TERMINALS)
LEARN AS "RF"
5827
SET HOUSE ID
5 8 2 7
SET HOUSE CODE
LOOP 1
(INTERNAL
SHOCK
5 8 2 7 B D
5827BD
SENSOR)
SET HOUSE CODE
(Green)
(Red)
(Yellow)
5 8 9 0
LEARN AS "RF"
INPUT
(LOOP)
1
(MOTION)