Application Bulletin 376
Installation Instruction for ProfIC Vario 6 Anion
The ProfIC Vario 6 Anion is a Professional IC Vario system
with Inline Dilution and Inline Ultrafiltration for the fully
automatic determination of anions or cations with sequential
suppression in very high concentrations in matrices
containing particles. This system enables users to dilute the
sample and eliminate bacteria or inorganic particles prior to
the analysis.

Table of contents

1.
Delivery Package ................................................... 2
IC ........................................................................... 2
Detector ................................................................. 2
Sample processor .................................................. 2
Accessories ........................................................... 2
Optional ................................................................. 2
2.
Installation .............................................................. 2
2.1.
Installation of the software ..................................... 2
2.2.
2.3.
2.4.
858 Professional Sample Processor ...................... 2
2.4.1.
2.4.1.1. Rinsing unit ............................................................ 3
2.4.1.2. Dilution unit and 800 Dosino .................................. 3
2.4.2.
Ultrafiltration cell .................................................... 4
2.5.
Interconnection of devices ..................................... 4
2.6.
940 Professional IC Vario ...................................... 5
3.
MagIC Net .............................................................. 5
3.1
Configuration.......................................................... 5
3.2
Method adjustment ................................................ 6
3.3.
Purge of the system ............................................... 7
3.4.
User defined determination .................................... 7
4.
Exemplary measurement ....................................... 8
5.
Optional equipment ................................................ 9
5.1.
Eluent Production Module ...................................... 9
5.2.
regeneration methods ............................................ 9
Page 1 of 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProfIC Vario 6 Anion and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Metrohm ProfIC Vario 6 Anion

  • Page 1: Table Of Contents

    Application Bulletin 376 Installation Instruction for ProfIC Vario 6 Anion The ProfIC Vario 6 Anion is a Professional IC Vario system Table of contents with Inline Dilution and Inline Ultrafiltration for the fully Delivery Package ........... 2 automatic determination of anions or cations with sequential IC ................
  • Page 2: Delivery Package

    Delivered with ProfIC Vario 6 Anion package: Article no. Article designation 2.1. Installation of the software All programs must be shut down first. Make sure no Metrohm instrument is connected to the PC. Install MagIC Net with the 2.940.1500 Professional IC Vario ONE/SeS/PP help of the MagIC Net - CD.
  • Page 3: Liquid Handling Station (Lqh Station)

    Application Bulletin 376 Installation Instruction for ProfIC Vario 6 Anion cable and the power supply cable. The controller cable (6.2151.000) is plugged into the plug “Contr.” on the 858 and connected to the IC device via USB. The sample processor initializes and lifts its Swing Head, once the IC device it is connected to is recognized by the software.
  • Page 4: Ultrafiltration Cell

    10. Pump tubing (6.1826.320) with yellow-orange stoppers for conveying the filtrate 11. Pump tubing connection with safety device (6.2744.160) 2.5. Interconnection of devices The whole setup of the ProfIC Vario 6 Anion packet is depicted here: Page 4 of 9...
  • Page 5: 940 Professional Ic Vario

    Application Bulletin 376 Installation Instruction for ProfIC Vario 6 Anion 13. MCS air aspiration capillary – connected to the CO adsorber cartridge 14. Sample aspiration capillary – PEEK, 0.97 mm ID, coming from the Ultrafiltration Cell (chapter 2.4.2, number 9) 15.
  • Page 6: Method Adjustment

    MagIC Net - CD. In the Please define the external positions 1, 2 and 3 according to window method, import the method for ProfIC Vario 6 Anion the picture below. Attention: The angles are only approximate from the installation CD: Go to File →...
  • Page 7: Purge Of The System

    1, all components of standard 10 have a tenth of the standard Vario_6_Anion.imet 1 concentration. In the window method, open the ProfIC Vario 6 Anion method Always use the standard number as the factor that lies and assign the following equipment: Assign the suppressor between the two solutions.
  • Page 8: Exemplary Measurement

    Application Bulletin 376 Installation Instruction for ProfIC Vario 6 Anion Exemplary measurement This data was recorded using a MSM Rotor A with the Adapter Vario on a Metrosep A Supp 15 - 150/4.0 column. Fluoride, chloride, nitrite, bromide nitrate, sulfate, and phosphate were measured as exemplary standard anions (5 ppm).
  • Page 9: Optional Equipment

    Application Bulletin 376 Installation Instruction for ProfIC Vario 6 Anion Optional equipment 5.1. Eluent Production Module The 941 Eluent Production Module creates fresh new eluent out of eluent concentrate and ultrapure water. For installation instructions and further information, please refer to the 941 Eluent Production Module Manual.

Table of Contents