Technical Communication Metrohm AG CH-9100 Herisau techcom@metrohm.com This documentation is protected by copyright. All rights reserved. This documentation has been prepared with great care. However, errors can never be entirely ruled out. Please send comments regarding possible errors to the address above.
General ................. 17 5.5.2 Connecting a USB hub ............17 5.5.3 Connecting a printer .............. 17 5.5.4 Connecting a balance ............18 5.5.5 Connecting a PC keyboard ............. 19 5.5.6 Connecting a barcode reader ..........20 ■■■■■■■■ 915 KF Ti-Touch...
Page 6
Switching the instrument on and off ....... 25 Fundamentals of operation ..........27 6.2.1 Touch-sensitive screen ............27 6.2.2 Display elements and controls ..........28 6.2.3 Status display ................ 29 6.2.4 Entering text and numbers ............. 30 7 Maintenance Index ■■■■■■■■ 915 KF Ti-Touch...
In addition to an introduction, safety instructions and an overview of the instruments, you will also find information about the installation and operation of the 915 KF Ti-Touch in addition to docu- ments regarding conformity and warranty. You will find the more detailed manual as a PDF file on the external storage medium included in the scope of delivery.
800 Dosino type with a dosing unit. You can, however, also use a 805 Dosimat with an exchange unit. Thanks to its compact construction, you can use the 915 KF Ti-Touch in a small space as a stand-alone titrator.
2.1.3 Intended use The 915 KF Ti-Touch is designed for usage as a titrator in analytical labora- tories. Its application field is volumetric Karl Fischer titration. This instrument is suitable for processing chemicals and flammable sam- ples.
This symbol draws attention to a possible hazard due to heat or hot instrument parts. WARNING This symbol draws attention to a possible biological hazard. CAUTION This symbol draws attention to possible damage to instruments or instrument parts. ■■■■■■■■ 915 KF Ti-Touch...
Page 11
■■■■■■■■■■■■■■■■■■■■■■ 2 Introduction NOTE This symbol highlights additional information and tips. ■■■■■■■■ 915 KF Ti-Touch...
The electrical safety when working with the instrument is ensured as part of the international standard IEC 61010. WARNING Only personnel qualified by Metrohm are authorized to carry out service work on electronic components. WARNING Never open the housing of the instrument. The instrument could be damaged by this.
Set up the instrument in a well-ventilated location (e.g. fume cup- ■ board). Keep all sources of flame far from the workplace. ■ Clean up spilled liquids and solids immediately. ■ Follow the safety instructions of the chemical manufacturer. ■ ■■■■■■■■ 915 KF Ti-Touch...
The correct disposal of your old instrument will help to prevent negative effects on the environment and public health. More details about the disposal of your old instrument can be obtained from your local authorities, from waste disposal companies or from your local dealer. ■■■■■■■■ 915 KF Ti-Touch...
■■■■■■■■■■■■■■■■■■■■■■ 4 Overview of the instrument 4 Overview of the instrument Front of the instrument 8 9 10 Figure 1 Front 915 KF Ti-Touch Display Fixed key [Home] Touch screen. Opens the main dialog. Fixed key [Back] Fixed key [Help]...
NTC). Two B sockets, 2 mm. double Pt electrodes. Socket F. MSB connector (MSB 1 and MSB 2) Power socket (Power) Metrohm Serial Bus. For connecting external For connecting the external power supply dosing devices, stirrers or a Remote Box. unit.
The instrument should be protected against excessive temperature fluctu- ations and direct sunlight. Connecting the power supply unit The 915 KF Ti-Touch has an external power supply unit for a 24 V power supply (DC). This is connected to the mains connection of the Ti-Touch. WARNING An incorrect mains voltage can damage the device.
Page 18
Ti-Touch and with the mains supply. CAUTION Switch off the Ti-Touch correctly by pressing the mains switch before you disconnect the electricity supply. If this is not done, then there is a danger of data loss. ■■■■■■■■ 915 KF Ti-Touch...
If the height of the KF titration cell has been adjusted correctly, the entire cell can be raised and swiveled as required by pressing the locking lever. ■■■■■■■■ 915 KF Ti-Touch...
Connecting MSB devices In order to connect MSB devices, e.g. dosing devices or Remote Box, the Ti-Touch has two connectors to what is referred to as the Metrohm Serial Bus (MSB). Various peripheral devices can be connected in sequence (daisy chain) at a single MSB connector (8-pin Mini DIN socket) and be control- led simultaneously by the Ti-Touch.
6 m. 5.4.1 Connecting a dosing device You can connect two dosing devices to the Ti-Touch. The types of dosing devices that are supported are: 800 Dosino ■ 805 Dosimat ■ ■■■■■■■■ 915 KF Ti-Touch...
Instruments that are controlled via remote lines and/or that send control signals via remote lines can be connected via the 6.2148.010 Remote Box. In addition to Metrohm, other instrument manufacturers also use similar connectors that make it possible to connect different instruments together.
5.5.1 General The 915 KF Ti-Touch has a USB connector (Type A socket) for peripheral devices with USB interface and for Sample Processors. If you wish to con- nect more than one device to the USB, you can use a commercially avail- able USB hub.
6.2125.020 + 6.2125.010 011 or 012 Also from Mettler: ME 42500 hand switch or ME 46278 foot switch Ohaus Voyager, Explorer, Analyti- Cable AS017-09 from Ohaus cal Plus Precisa balances with RS-232-C 6.2125.080 + 6.2125.010 interface ■■■■■■■■ 915 KF Ti-Touch...
Connect the PC keyboard as follows: 1 Connect the USB plug of the keyboard with the USB connector of the Ti-Touch (Type A). 2 Enter and configure the keyboard in the device manager of the Ti-Touch. ■■■■■■■■ 915 KF Ti-Touch...
If you wish to integrate your Ti-Touch in an automation system, then you can connect the following Sample Processors to the USB connector: 814 USB Sample Processor ■ 815 Robotic USB Sample Processor XL ■ 810 Sample Processor (from firmware version 5.915.0040) ■ ■■■■■■■■ 915 KF Ti-Touch...
3 Configure the Sample Processor in the device manager. Setting up the titration vessel The tutorial for the 915 KF Ti-Touch includes a detailed description of how to set up the Karl Fischer titration cell and what needs to be taken into account while doing so.
Connecting the temperature sensor A temperature sensor of the Pt1000 or NTC type can be connected to the Temp. connector. Connect the temperature sensor as follows: 1 Plug the temperature sensor plugs into the Temp. sockets of the Ti-Touch. ■■■■■■■■ 915 KF Ti-Touch...
Connecting the Ti-Touch to a network The 915 KF Ti-Touch has a network connection (Ethernet). This can be used to integrate your Ti-Touch in your network. You can, for example, store data on a PC within the network or print reports on a network printer.
Page 30
■■■■■■■■■■■■■■■■■■■■■■ 5.8 Connecting the Ti-Touch to a network Figure 8 Connecting the Ti-Touch to a network ■■■■■■■■ 915 KF Ti-Touch...
Proceed as follows: Press the power switch on the left-hand side of the back panel of ■ the 915 KF Ti-Touch. The 915 KF Ti-Touch is initialized. A system test is performed. This process takes some time. ■■■■■■■■ 915 KF Ti-Touch...
Page 32
All tubings and the cylinder are rinsed with the Prepare function. The preparing of the buret unit is described in the chapter Manual control of the detailed manual. Confirm the message with [OK]. ■ The main dialog is displayed: ■■■■■■■■ 915 KF Ti-Touch...
You can always return to the main dialog by touching [ In order to activate an element on the 915 KF Ti-Touch user interface, just touch the screen with your fingertip, finger nail, the eraser of a pencil or a stylus (special tool for operating instruments with touch-sensitive screens).
In the other dialogs, the title bar shows the headings of the next upper level and of the displayed dialog. This is an aid for orientation during navi- gation through the user dialog. Table 2 Screen elements Buttons open a new dialog when they are tap- ped. ■■■■■■■■ 915 KF Ti-Touch...
The instrument is in normal status. The working medium is being conditioned. Conditioning has been paused. The working medium is conditioned. A method has been started. A method has been paused. An action has been started in manual control. ■■■■■■■■ 915 KF Ti-Touch...
[A…Z]. The upper-case letters are displayed again by tapping. [0…9] Numbers and mathematical characters are dis- played. [Special charac- Special characters are displayed. You can use the ters] button [More] to navigate through all available characters. ■■■■■■■■ 915 KF Ti-Touch...
Page 37
You can select the result variable by touching [R1]. NOTE A commercially available USB keyboard can be connected to make text and numerical input easier. The key assignment is described in the chapter Device manager of the detailed manual. ■■■■■■■■ 915 KF Ti-Touch...
Maintenance The electronic and mechanical functional groups of Metrohm instruments can and should be checked by specialist personnel from Metrohm as part of a regular preventive maintenance schedule. Please ask your local Metrohm representative regarding the precise terms and conditions involved in concluding a corresponding maintenance agreement.