Technical Features - Datalogic T4 Series Quick Start Manual

Table of Contents

Advertisement

TECHNICAL FEATURES

TECHNICAL FEATURES
ELECTRICAL FEATURES
Power
Supply Voltage
Consumption (max)
Communication Interfaces
RS232
Ethernet
Inputs
Input 1(External Trigger) and Input 2 Opto-coupled and polarity insensitive
Max. Voltage
Max. Input Current
Outputs
Output 1, Output 2 and
Strobe/Output 3
V
(I
= 0 mA) Max.
Out
Load
V
(I
= 10 mA) Max.
Out
Load
P
= V
x  I
Max.
D
Out
Load
OPTICAL FEATURES
Image Sensor
Image Format
Frame Rate
ENVIRONMENTAL FEATURES
Operating Temperature
Storage Temperature
Max. Humidity
Vibration Resistance
EN 60068-2-6
Shock Resistance
EN 60068-2-27
2
Protection Class
EN 60529
PHYSICAL FEATURES
Dimensions
Weight (with lens)
Material
Parameter Storage
USER INTERFACE
LED Indicators
Keypad Button
1
High ambient temperature applications should use metal mounting bracket for heat dissipation.
2
Requires correct connection to IP67 cables with seals and Lens Cover mounting.
10-30 Vdc ± 20%
T40 – 1 A ( Max); T47 – 1.05 A ( Max); T49 – 1.2 A ( Max)
2400 to 115200 bit/s
10/100/1000 Mbit/s, Gigabit Ethernet
30 Vdc
10 mA
Opto-coupled
30 Vdc
1.8 Vdc
170 mW
CCD
T40 – 640 x 480; T47 - 1600 x 1200; T49 - 2456 x 2058
T40 – 60; T47 – 15; T49 - 15
1
0 to 45 °C (32 to 113 °F)
-20 to 70 °C (-4 to 158 °F)
90% non-condensing
1.5 mm @ 5 to 9 Hz; 0.5 g @ 9 to 150 Hz 2 hours on each axis
2 g @ 70 to 200 Hz; 2 hours on each axis
30g; 11 ms
3 shocks on each axis
IP65
123 x 60 x 101 mm (4.84 x 2.36 x 3.98 in)
539 g. (19 oz.)
Aluminum
Permanent memory (Flash)
Power, Busy/Trigger, Out 1; Out 2; Out 3, Online
Reset
21