Power Supply - Datalogic T4 Series Quick Start Manual

Table of Contents

Advertisement

POWER SUPPLY

+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
Output 1 +
O1-
Output 1 -
O2+
Output 2 +
O2-
Output 2 -
O3A
Strobe + / Output 3 + (See Note)
O3B
Strobe - / Output 3 -
TX
Transmit
RX
Receive
SGND
Signal Ground (See Caution)
Note: The strobe signal connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length
value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is active.
Do not connect GND and SGND to different (external) ground references.
GND and SGND are internally connected through filtering circuitry which
can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
CAUTION
To avoid electromagnetic interference when the camera is connected to a
CBX connection box, verify the jumper positions in the CBX as indicated in
its Installation Manual.
NOTE
POWER SUPPLY
The T4x-Series does not support sourcing power towards the CBX through
the CBX "power from device" source jumper setting. Power must be
supplied to the CBX as shown below.
NOTE
To power the camera and/or I/O devices through the CBX, power must be supplied to the
CBX500 spring clamp terminal pins as shown in Figure 4:
The power must be between 10 and 30 Vdc only.
It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the
appropriate jumper in the CBX connection box. See the CBX Installation Manual for details.
Outputs
RS232 Interface
Figure 4 - Power Supply Connections
11