Technical Data; A) General Information; B) Weather Station - Renkforce 2377869 Operating Instructions Manual

Rc color display weather station with 7-in-1 professional sensor
Table of Contents

Advertisement

Available languages

Available languages

17. Technical data

a) General information

Indoor temperature
Outdoor temperature
Indoor humidity
Outdoor humidity
Rainfall
Barometric pressure
Wind speed

b) Weather station

Battery ..............................................................1x CR2032
Current consumption ........................................max. 162 mA
Noise level (alarm) ............................................min. 70 dB
Operating conditions .........................................-5 to +50 °C, 20 – 90 % RH (non-condensing)
Storage conditions ............................................-20 to +60 °C, 10 – 80 % RH
Dimensions (W x H x D) ...................................168 x 136 x 24 mm
Weight ..............................................................356 g (with battery, without adaptor)
Display range
-5 to +50 °C
-40 to +60 °C
20 - 90 % RH
1 - 99 % RH
0 - 9999 mm
540 - 1100 hPa
0 - 112 mph, 50 m/s,
180 km/h, 97 knots
Accuracy
±1 °C (0 – 40 °C)
±2 °C (<0 °C or >40 °C)
±0.4 °C (5.1 – 60 °C)
±1 °C (-19.9 – 5 °C)
±1.5 °C (-40 – -20 °C)
±8 % RH (20 – 40 % RH)
±5 % RH (41 – 70 % RH)
±8 % RH (71 – 90 % RH)
@ 25 °C
±6.5 % RH (1 – 20 % RH)
±3.5 % RH (21 – 80 % RH)
±6.5 % RH (81 – 99 % RH)
@ 25 °C
The greater of ±7 % or
±0.4 mm (1 tip)
±5 hPa (700 – 1100 hPa)
±8 hPa (540 – 696 hPa)
±0.15 inHg (20.67 – 32.48 inHg)
±0.24 inHg (15.95 – 20.55 inHg)
±3.8 mmHg (525 – 825 mmHg)
±6 mmHg (405 – 522 mmHg)
Typical at 25 °C
±0.5 m/s (<5 m/s)
±6 % (>5 m/s)
Resolution
0.1 °C
1 %
0.4 mm
1 hPa
0.1 m/s
63