2.4 Wiring

CAUTION: The following connection order is recommended for
optimal safety.
CAUTION: Do not entangle all wiring together. Communication
cable and power wires should be as far as possible to avoid
interfering communication signal transmission.
CAUTION: The controller is a negative ground controller. Any
negative connection of solar or battery can be earth grounded as
required.
CAUTION: For mobile applications, be very certain that all wirings
are connected securely. Use cable clamps to prevent cables from
swaying when the vehicle is in motion. Unsecured cables create
loose and resistive connections which may lead to excessive
heating and/or fire.
① Remote Temperature Sensor Connection
CAUTION: The controller will perform temperature compensation
for charging parameters according to the device temperature.
CAUTION: Equipment Damage! Never place the temperature
sensor inside a battery. Both the RTS and the battery will be
damaged.
※Please remove the terminal
protective cover before wiring.