Status
Output Channel State
Indicator
(Off)
All device outputs are disconnected from their voltage generation sources through
output disconnect relays.
Green
At least one device output is connected to a voltage generation source.
Red
The device has a fault or is in error due to the voltage generated or measured by
the device. Refer to the driver software for possible sources. The device will not
operate until the error is cleared and/or the device is reset.
Table 2. LED Voltage Status Indicator
Pinout
The following figure and table provide detailed signal information for the PXIe-4162
connector.
Bundle
Channel Pin Signal Description
A
0
62 Output HI
61 Sense HI
CH0 Guard
CH0 Output HI
CH0 Sense LO
CH0 Sense HI
NC
CH2 Guard
CH2 Output HI
CH2 Sense LO
CH2 Sense HI
CH3 Guard
CH3 Output HI
CH3 Sense LO
CH3 Sense HI
NC
CH5 Guard
CH5 Output HI
CH5 Sense LO
CH5 Sense HI
CH6 Guard
CH6 Output HI
CH6 Sense LO
CH6 Sense HI
NC
CH8 Guard
CH8 Output HI
CH8 Sense LO
CH8 Sense HI
CH9 Guard
CH9 Output HI
CH9 Sense LO
CH9 Sense HI
NC
CH11 Guard
CH11 Output HI
CH11 Sense LO
CH11 Sense HI
21
Calibration HI
42
CH1 Output HI
62
20
41
CH1 Sense HI
61
19
40
60
18
CH1 Guard
39
CH1 Sense LO
59
17
38
37
CH4 Output HI
57
15
36
56
14
CH4 Sense HI
35
CH4 Guard
55
13
34
54
12
CH4 Sense LO
33
10
CH0 to 11 Output LO
31
51
9
CH7 Output HI
30
50
8
CH7 Sense HI
29
49
7
CH7 Guard
28
48
6
CH7 Sense LO
27
26
CH10 Output HI
46
4
25
CH10 Sense HI
45
3
24
CH10 Guard
44
2
23
CH10 Sense LO
43
1
22