Gauges Calibration - rav G3.150 Translation From The Original Instructions

Table of Contents

Advertisement

RAVAGLIOLI S.p.A.
G3.150 - GP3.150 - G3.150S - GP3.150S - G3.150WS - GP3.150WS - G3.150WSPLUS - GP3.150WSPLUS - G3.150SA - G3.150WSA
- Remove the weight from 100 g from the outside of the
wheel and apply it on the inner side at "12 o'clock".
AT THIS POINT TAKE THE WEIGHT
POSITIONED ON THE EXTERNAL
SIDE AND PLACE IT EXACTLY
IN THE SAME POSITION BUT ON
THE INTERNAL SIDE, HELPING BY
DRAWING A LINE ON THE TYRE
AS A REFERENCE (SEE FIGURE
BELOW).
- Close the guard to perform the 3rd spin of the wheel
(100 g weight placed on the inside wheel).
At the end of the rotation, the video screen below will
be displayed to indicate that the operation is finished.
WHEN THE OPERATION IS CON-
CLUDED, REMOVE THE WHEEL
FROM THE CHUCK AND PERFORM
A COMPLETE CALIBRATION PRO-
CEDURE "0" (ZERO) CHUCK AS
DESCRIBED IN PAR. 15.3.1.
INSTRUCTION, USE AND
MAINTENANCE MANUAL

15.3.3 Gauges calibration

Press the button
following screen page on the monitor:
Distance-diameter caliper calibration
Press the button
page on the monitor:
Page 78 of 91
(Fig. 72 ref. 3) to display the
1
KEY
1 – Distance-diameter caliper calibration
2 – Calibration of external data gauge/automatic
width measuring unit
THE NUMERICAL VALUES SHOWN
IN THE FIGURES BELOW ARE
PURELY ILLUSTRATIVE.
to display the following screen
1297-M058-00
2
EN