15.1.1 Lower weight limit

Correction weight below a certain limit is normally
shown equal to zero. This limit can be set from 10 g
to 1 g (from 0.5 oz to 0.05 oz).
At the end of the spin however, by pressing the button
, the weight can be displayed with maximum
resolution of 1 g (0.05 oz), not considering the set
lower limit.
LOWER LIMIT FACTORY SETTING
FOR DYNAMIC WHEEL BALANC-
ING MODE IS 5 g (0.25 oz). THE
LOWER LIMIT FOR ALL THE OTH-
ER MODES IS SET AT 7 g (0.35 oz).
1
2
3
4
KEY
1 – Lower weight limit in the DYNAMIC program
to display "OK" (default value 5 g (0.25 oz))
2 – Lower weight limit in the ALU-STATIC program
to display "OK" (default value 7 g (0.35 oz))
2 – Weights display resolution (default value 5 g
(0.25 oz))
4 – Weight % reduction in ECO-WEIGHT function
(0 ÷ 200) (default value 100)
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Default
Work range
values
g
oz
g
5
0.25
2 ÷ 50
0.05 ÷2.00
7
0.35
2 ÷ 50
0.05 ÷2.00
5
0.25
2 ÷ 50
0.05 ÷2.00
0 - 50 - 100
0 - 50 - 100
100
100
150 - 200
150 - 200
%
%
15.1.2 Setting adhesive weight dimensions
and static threshold percentage
To ensure the balancing machine precisely calculates
the dimensions and total adhesive weights, set the
height (thickness) and width of the adhesive weights
at your disposal (see Fig. 68).
Fig. 68
oz
To carry out this setting, press the icon
will see the following screen:
1
2
KEY
1 – Weights thickness (height) (default value 4 mm)
2 – Weights width (default value 19 mm)
From this screen page, change the size values of weights
using the buttons