4 Installation

4.1 Preinstallation

WARNING:
• Disconnect and lock out electrical power before installing or servicing the unit.
• Do NOT install this pump in swimming pools or marine areas.
• Risk of electric shock. This pump is supplied with a grounding conductor and grounding-
type attachment plug. Install or connect to a circuit that is protected by a GFCI, ground
fault circuit interruptor.
• Electrical supply must be in accordance with the specifications given on the pump's
nameplate.
• Failure to follow these instructions could result in serious personal injury, death and/or
property damage.
These general requirements apply:
• The electrical outlet must be within the length limitations of the pump power cord and at
least four feet above floor level to minimize possible hazards from floor conditions.
• Do not use pumps in water over 140°F (60°C)
• Do not use pumps in mud, sand, cement, oil, or chemicals.
• Do not use a sump pump as a trench or excavation pump, or for pumping sewage,
gasoline, or other hazardous liquids.
• Do not modify the pump in any way.
• Do not lift or carry the pump by the power cord.
• Do not remove any tags from pump or cords.
• Do consider a two pump system with an alarm where an installation may become
overloaded.
• Do inspect and test system for proper operations at least every three months.
• Always verify that the pump nameplate Amps, Voltage, Phase, HP rating match the
power supply.
• Be sure to record the model numbers and serial numbers from the pump for future
reference.

4.1.1 Pump location guidelines

Guideline
Make sure that the space around the pump and
switch are sufficient.
The depth must be deeper than the minimum depth
at which the switch turns the pump on.
Determine whether a cover is required.

4.1.2 Piping checklist

Guideline
Discharge pipe should be the same size as the
pump.
Sump and Effluent Pump INSTRUCTION MANUAL
Explanation
The switch must be able to operate freely.
As an example, if the pump turns on at 7.50", the
basin must be deeper than 7.50".
Install a cover when:
• Installation is in an area where debris could enter
and clog the pump.
• In a traffic area such as a basement where
children and pets are allowed. A bolt-on or child-
proof cover is recommended.
Explanation
This insures optimum performance. Undersized
pipe can dramatically reduce the flow and waste
energy.