INSTALLATION

STEP 1
Remove shipping plugs from Quad pump ports. Some
water from factory testing may spill out
STEP 2
Install inlet A and discharge, B port connectors. Firmly
push slide clips C forward to lock port connectors in
place.
STEP 3
Slide rubber mounts fully into 4 mounting tracks.
STEP 4
Mount pump vertically, with pump head down or
ELECTRICAL
The pump should be wired into an individual (dedicated) circuit, controlled with an UL/C-UL certified double pole switch
rated at or above the fuse ampere indicated on the pump motor label.
On 12 and 24 volt DC pumps, the red lead is positive and should be connected to the battery plus (+) terminal. The black
lead is ground and should be connected to the battery negative (–) terminal. Improper duty cycle and/or rapid start stop
conditions will cause the internal thermal breaker (if equipped) to trip, or can cause premature motor failure due to
excessive heat.
WARNING: DO NOT USE A PUMP IF IT PRESENTS SOME DAMAGE SUCH AS BURNED
OR BROKEN PRESSURE SWITCH, EXPOSED ELECTRIC WIRE AND/OR CONTACTS.
Recommended DC Voltage wire sizes. Total wire length – feet (meters).
Red
Pump
0-20
voltage
(0-6)
12 volt
#14 AWG
(2.5 mm²)
24 volt
#16 AWG
(1.5 mm²)
horizontally in an able location. If mounting vertically,
motor up, attach motor mounts first then pump head
mounts, while supportingweight of pump.
STEP 5
Use 3/4" I.D. flexible hose (preferably braided or
reinforced). Use hose clamps on the slip-on barb hose
connections.
STEP 6
Install a 3/4" in line strainer #01740000 in accessible
location between sea cock and pump inlet. This strainer
or equivalent is required for pump warranty to be valid.
Black
Fuse
Switch
20-35
(6-11)
#12 AWG
(4 mm²)
#14 AWG
(2.5 mm²)
3
Battery
35-55
(11-17)
#10 AWG
(6 mm²)
#12 AWG
(4 mm²)

Advertisement