WARNING: FIRE HAZARD
Wiring must comply with applicable
electrical standards and include a properly
sized fuse or circuit breaker. Improper wiring can cause a fire
resulting in injury or death.
CAUTION: Suggested wiring information is given
as a reference. For proper information please
reference local wiring codes and specification
guidelines.
Model
Volts
R4426343A
24V
R4320143A
12V
R4426143A
12V
R4425505A
12V
Wire Size Table
Total Wire Length - feet (meters)
Pump
0 - 20 ft
Voltage
(0 - 6 m)
#14 AWG
12 VDC
(2.5 mm²)
#16 AWG
24 VDC
(1.5 mm²)
ELECTRICAL INSTALLATION
Electrical Hazard:
WARNING: Make sure that all connections are
performed by qualified installation technicians and
in compliance with the regulations in force.
WARNING: Before starting work on the unit,
make sure that the unit and the control panel are
isolated from the power supply and cannot be
energized.
Installation:
WARNING:
• Observe accident prevention regulations in force.
• Use suitable equipment and protection.
• Always refer to the local and/or national regula-
tions, legislation, and codes in force regarding
the selection of the installation site, plumbing,
and power connections.

Electrical requirements:

The local regulations in force overrule specified requirements
listed below.
Electrical connection checklist
Check that the following requirements are met:
• The electrical leads are protected from high temperature,
vibrations, and collisions.
• The current type and voltage of mains connection must corre-
spond to the specifications on the data plate on the pump.
Amps
Fuse
6.0 A
10 A Required
12.0 A
15 A Required
12.0 A
15 A Required
12.0 A
15 A Required
20 - 35 ft
35 - 55 ft
(6 - 9 m)
(9 - 12 m)
#12 AWG
#10 AWG
(4 mm²)
(6 mm²)
#14 AWG
#12 AWG
(2.5 mm²)
(4 mm²)
Electrical Installation
Diagram
Figure 5
15A
Inline fuse
OR
Fuse
15A
Breaker
12V DC Battery

OPERATION

Figure 6
• Initial Start up
• Open all faucets
• Turn pump switch "ON"
NOTE: Expect a 10 second delay for power up.
• When water is free of air, turn all valves off beginning with the
valve closest to the pump (Figure 6)
Important: Do not operate the pump more than 15 minutes
continuously.
4
Green
ground
Gray
Red
Black
Initial Start Up
Demand Off
Demand On