3 Unit Installation

3.1 Foundation Requirements

3.2 Bolt installation - pump to concrete
• Use some type of expansion fitting in order to facilitate easy servicing. Insert
the female portion into a suitable hole in the pad so that its top surface is
flush with the pad surface. Thus, when the hold-down bolts are removed, the
motor can be removed by sliding it back from the pump.
2
1. Pour grout here up to top surface / plane of base plate
2. Nut
3. Washer
4. Base plate
5. Shims or levelling wedges
6. Bolt sleeve
7. Anchor bolt
8. Concrete foundation
9. Position levelling wedges / shims on both sides of each anchor bolt
Notes:
• Distance from the base plate to the edge of the foundation to be greater than or equal to
1.5".
• Foundation weight should be greater than or equal to 2.5 times of pump weight.