  • Page 1 FRM-173 Series LCD Monitor User Manual...
  • Page 3 Product Information Model: FRM-173 Series Pull-out Rackmount LCD Monitor Version: V010001 Release Date: March 12th, 2015 Company OSEE TECHNOLOGY CO., LTD. Contact Information No.22 Building, No.68 zone, Beiqing Road, Haidian District, Address: Beijing, China Post Code: 100094 (+86) 010-62434168 Tel:...
  • Page 4: Contents

    About this manual Important The following symbols are used in this manual:  The further information or know-how for described subjects above which helps user to understand them better.  The safety matters or operations that user must pay attention to when using this product.
  • Page 5: Table Of Contents

    Contents Contents ......................I Chapter 1 Overview ..................1 Chapter 2 Safety ..................... 3 Chapter 3 Unpack and Installation ............... 7 Chapter 4 FRM-173 Features............... 11 4.1 Front Panel Features ................ 13 4.1.1 Arrangement of Front Panel ............13 4.1.2 Operation of Front Panel ..............13 4.2 Rear Panel Features ................
  • Page 6 6.2.1 ADJUST Menu ................57 6.2.2 VIDEO DISPLAY Menu ..............59 6.2.3 SYSTEM Menu ................59 6.2.4 Other Menus ................... 60 6.3 Parameter Settings ................61 Chapter 7 Specifications ................65...
  • Page 7: Chapter 1 Overview

    The front frame of the unit comes in a slim bezel design made from rubber mold. The professional TFT glass at full resolution of 1920 x 1080 with LED backlight makes the FRM-173 series LCD monitor capable of reproducing a natural color at quickest response time. In addition, the unit boasts a full wide viewing angle as well as excellent brightness and contrast ratio.
  • Page 8 Overview  Featuring PBP and PIP, dual 3G-SDI capable under PBP mode  Supporting waveform/vector scope, audio metering bar, TC, IMD and  Supporting varied color temperature, varied scan modes, flexibility in marker setting, Blue Only/Monochrome mode Functionality  Supports MARKER, Time Code, MET display ...
  • Page 9: Chapter 2 Safety

    Safety Chapter 2 Safety FCC Caution Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 10 Safety Warnings Read, keep and follow all of these instructions for your safety. Heed all warnings. Device  Install in accordance with the manufacturer's instructions.  Do not beat with a hard object or scratch the LCD display. Do not make the freeze picture displaying on the screen time too long, ...
  • Page 11 Safety heat.  A nameplate indicating operating voltage, etc., is located on the rear panel. The socket-outlet shall be installed near the equipment and shall be  easily accessible. Power Supply Cord  Do not defeat the safety purpose of the polarized or grounding-type plug.
  • Page 13: Chapter 3 Unpack And Installation

    Unpack: When unpacking the components of FRM-173 monitor, please verify that none of the components listed in Table 3.1 are damaged or lack. If there is any missing, contact your distributors or OSEE for it. Table 3-1 Packing List Item...
  • Page 14 Unpack and Installation Step 1 Hold the handler of the monitor, and rotate it slowly paralleled with the frame. Step 2 Press the spring pieces into the rail simultaneously at both side of the rail(shown as point 2), and push in the monitor. Free your fingers after the spring pieces slid into the rail, and push the monitor into the rail.
  • Page 15 And do not hurt your finger.  The FRM-173 series monitor can be installed in 18"~ 20" rack, or opening, or folded placing. Connect required cables for signal input and output. For BNC connections use 75Ω...
  • Page 16 Unpack and Installation power or following the local power supply conditions. Make sure the power cord grounding well.  The factory default value for IP address is 192.168.1.86.
  • Page 17: Chapter 4 Frm-173 Features

    FRM-173 Features Chapter 4 FRM-173 Features This chapter describes the features of FRM-173 monitor. The features of FRM-173 monitor are as shown in Figure 4-1 after installed and powered on: Status Information SDI1 AFD CC 1080I59.94 Area Marker Safe Marker Audio Meter 1 2 3 4 5 6 7 8 Center Marker...
  • Page 18 FRM-173 Features image. You can set whether to display it or not in MARKER menu. Audio Meter It is displayed for audio monitoring. You can set its groups, direction, position and mode in AUDIO menu. Timecode It is displayed at the bottom of the image, the format is HH:MM:SS:FF, if there is no timecode available, the monitor will display --:--:--:--.
  • Page 19: Front Panel Features

    FRM-173 Features 4.1 Front Panel Features It will introduce the arrangement and the operations of the buttons in front of the panel in the following. 4.1.1 Arrangement of Front Panel There are a series of buttons at the bottom of the screen, and these buttons are used to control the screen menu items.
  • Page 20 FRM-173 Features The functionality and usage of the buttons at the front panel are as follows: INPUT Select the input signal. Press this button to display the input source menu at the right top corner of the screen, as shown in Figure 4.1-2. Use it to select an input signal source, press it again to toggle among these input signal items.
  • Page 21 FRM-173 Features This button is a FUNCTION button. The function can be set via the FUNCTION menu. Open the FUNCTION menu after the first time, the selected function will remain.  OPERATION: Press F1 to display the function menu list in the center of the screen, as shown in Figure 4.1-4.
  • Page 22 FRM-173 Features FACTORY RESET Factory Reset Now? Figure 4.1-5 Reset Menu List It is used to activate to F3 function button. The operation is as the same as F1's. It is used to activate to F4 function button. The operation is as the same as F1's.
  • Page 23 FRM-173 Features  Confirm the value selection: press ENTER button to confirm the value selection.  Adjust Menu: when not displaying the Main menu, press ENTER button to display the adjust menu list, as shown in Figure 4.1-6, toggle among these menu items: VOLUME, BRIGHTNESS, CONTRAST, CHROMA.
  • Page 24: Rear Panel Features

    FRM-173 Features Used to power on or standby, and the light in the button will indicate the status of the power. If the light is green, the monitor is powered on, if the light is flashing, the monitor is standby. ...
  • Page 25: Operations Of Rear Panel

    FRM-173 Features Power Input Headphone Output Connector (3.5mm stereo Jack) Ethernet RS485 In/Out GPI interface Audio Input Video Input: LINE2(Pr) IN, feed the component Pr signal. Video Input: LINE2(Pb/C) IN, feed the component Pb, or component C signal. Video Input: LINE2(CVBS/Y) IN, feed the composited LINE2, or component Y signal.
  • Page 26 FRM-173 Features  Only use the adapter and the power cord specified by the manufacture for your safety! Headphone Output Connector It provides one headphone output connector, 3.5mm stereo Jack. Ethernet (RJ-45) It provides one 10/100M Ethernet connector. It is used to connect with a computer to modify the network settings.
  • Page 27 FRM-173 Features Table 4.2-2 The Relationship of GPI Pins and Channel Values Pin No. Channel Value Pin 1 GPI1 Pin 2 GPI2 Pin 3 GPI3 Pin 4 GPI4 Pin 5 GPI5 Pin 6 GPI6 Pin 7 Pin 8 Audio Input interface It provides four audio input interfaces, 5dBu, impedance≥47K, RCA connector.
  • Page 28: Supported Signal Format

    FRM-173 Features Figure 4.2-3 Video Input Interfaces HDMI It provides one HDMI input interface, HDMI Type-A connector with a fastener. Video Input Interface (BNC) It provides two SDI input interfaces, one is labeled as SDI1 IN, and the other is SDI2 IN. Video Output Interface (BNC) It provides one SDI output interfaces.
  • Page 29 FRM-173 Features VIDEO HDMI YPBPR 720P25    720P30/29.97       720P50 720P60/59.94    1080SF24/23.97    1035I60/59.94    1080I50    1080I60/59.94    1080P24/23.97   ...
  • Page 31: Chapter 5 Functionality Of The Main Menu

    Functionality of the Main Menu Chapter 5 Functionality of the Main Menu This chapter describes the structure and functionality of the main menu, and introduces how to modify and customize the menu settings. The main menu includes the following menu items, as shown in Figure5-1. Figure 5-1 Main Menu 5.1 Main Menu Press the MENU button at the bottom of the front panel, the main menu is...
  • Page 32 Functionality of the Main Menu The menu interface is divided into three parts: Main Menu List It contains the title of the Main menu and several sub-menu items. The title of this list is MAIN. Press UP or DOWN to access the corresponding menu item.
  • Page 33 Functionality of the Main Menu Figure 5.1-3 A Main Menu Item Is Selected  when in the sub-menu item, it shows that this sub-menu item is selected, and the control icon is displayed as a yellow rectangle in front of it, as shown in Figure 5.1-4: Figure 5.1-4 A Sub-menu Item Is Selected ...
  • Page 34: Status Menu

    Functionality of the Main Menu The following will introduce the contents and functionality of these sub-menu items in sorts. 5.1.1 STATUS Menu The STATUS menu items are used to describe the current status information of the monitor, the menu items are as shown in Figure 5.1-6: MAIN STATUS INPUT...
  • Page 35: Input Select Menu

    Functionality of the Main Menu Items Default Value Domain Range Description FAST OFF/ON Show the fast mode. MODE Show screen SD ASPECT 16:9 16:9/4:3 Aspect Ratio. Show the production MODEL FRM-173-3HSV model. SERIAL Show serial FRM1732014070001 NUMBER number. 192.168.1.86 Show the IP address. ADDRESS Show color...
  • Page 36: Marker Menu

    Functionality of the Main Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-2: Table 5.1-2 The Description of INPUT SELECT Menu Items Default Items Domain Range Description Value SDI1 ON/OFF Enable/Disable SDI1 input SDI2 ON/OFF...
  • Page 37 Functionality of the Main Menu Table 5.1-3 The Description of MARKER Menu Items Default Items Domain Range Description Value Set whether to show all of the markers. It is the main switch for MARKER OFF/ON area marker, center marker safety marker.
  • Page 38: Audio Menu

    Functionality of the Main Menu Default Items Domain Range Description Value background, use area marker mat. line for area marker edge only  HALF: 50% Background brightness  BLACK: all black Set whether to show the CROSS HATCH OFF OFF/ON cross hatch.
  • Page 39 Functionality of the Main Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-4: Table 5.1-4 The Description of AUDIO Menu Items Default Items Domain Range Description Value Select the audio source. ...
  • Page 40: Display Menu

    Functionality of the Main Menu Default Items Domain Range Description Value  TOP LEFT: top left When the value of METER DIRECTION HORIZONTAL, choose the followings for Meter Position:  BOTTOM   MODE1: simple audio meter  MODE2: audio meter METER DIS Select displayed...
  • Page 41 Functionality of the Main Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 5.1-5: Table 5.1-5 The Description of DISPLAY SETUP Menu Items Default Items Domain Range Description Value Set whether to display STD information.
  • Page 42 Functionality of the Main Menu Default Items Domain Range Description Value   D-VITC Set whether to display TC, and TIME CODE select a mode for TC display.   VITC Thereinto, the value of LINE WFM is different according to the type of input signal, as shown in Table 5.1-6.
  • Page 43: Close Caption Menu

    Functionality of the Main Menu  Please refer to the international standard SMPTE2016-1-2007 for the details about AFD display. 5.1.6 CLOSE CAPTION Menu The CLOSE CAPTION menu items are used to adjust the parameters displayed on the screen, the menu items are as shown in Figure 5.1-10: MAIN CLOSE CAPTION CLOSED CAPTION...
  • Page 44: Config Menu

    Functionality of the Main Menu 5.1.7 CONFIG Menu The CONFIG menu items are used to adjust the parameters defined by customers, the menu items are as shown in Figure 5.1-13: MAIN CONFIG FAST MODE STATUS INPUT SELECT FILM MODE DETECT MARKER SUB IN TYPE AUDIO...
  • Page 45 Functionality of the Main Menu Default Items Domain Range Description Value PIP SIZE LARGE SMALL/LARGE Set the size of PIP BOT LEFT:  bottom left  BOT RIGHT: PIP POSITION BOT LEFT Set the position of PIP bottom right  TOP RIGHT TOP LEFT ...
  • Page 46 Functionality of the Main Menu  In PBP mode, the relationship of the main picture and the slave picture is as shown Figure 5.1-15: Main Slave Picture Picture Figure 5.1-15 PBP Mode In PBP mode, it displays the WFM or Audio Meter only for the signal of the current picture.
  • Page 47: Color Temp Menu

    Functionality of the Main Menu right corner of the screen.  When the AUTO STANDBY is set to ON, the device will be standby when the signal is disappeared for 60s.  The length of LOCK NUMBER is up to 8 characters, you can use the combination of these characters: number (0 to 9) and letter (A to Z).
  • Page 48: Function Key Menu

    Functionality of the Main Menu Table 5.1-10 The Description of COLOR TEMP Menu Items Items Default Value Domain Range Description  USER1: Customized by user USER2:  Customized by COLOR user Set color temperature TEMP  D32: 3200K  D50: 5000K ...
  • Page 49 Functionality of the Main Menu The FUNCTION KEY menu items are used to define parameters to F1 and F2, the menu items are as shown in Figure 5.1-17: MAIN FUNCTION KEY SCAN STATUS INPUT SELECT NATIVE ASPECT MARKER AUDIO DISPALY CLOSE CAPTION CONFIG COLOR TEMP...
  • Page 50: Gpi Menu

    Functionality of the Main Menu NORMAL OVER UNDER Set the function button as [SCAN], press the button continuously to activate various scan modes.  OVER: Zooms in/out of the image to 96% of its original size without changing the aspect ratio. ...
  • Page 51 Functionality of the Main Menu Items Default Value Domain Range Description MARKER, ASPECT, NATIVE, OVER SCAN, UNDER SCAN, BLUE ONLY, MONO, DELAY, DELAY, DELAY, SDI1, SDI2, LINE1, LINE2, HDMI, TALLY GREEN, TALLY RED GPI2 TALLY RED the same as GPI1 Set a function to GPI2 GPI3 UNDEF the same as GPI1...
  • Page 52: Imd Menu

    Functionality of the Main Menu Items Function Trigger Switch scan mode between OVER SCAN Low: OVER; High: NORMAL over and normal. Switch scan mode between UNDER SCAN Low: UNDER; High: NORMAL under and normal. Switch between blue only Low: BLUE ONLY;...
  • Page 53 Functionality of the Main Menu MAIN IMD DISPLAY STATUS INPUT SELECT IMD COLOR MARKER IMD CHARACTER XXXXXXXXXXXXXXXX AUDIO IMD PROTOCOL LOCAL DISPALY IMD ID CLOSE CAPTION IMD NAME XXXXXXXXXXXXXXXX CONFIG BAUD RATE 38400 COLOR TEMP LED TALLY FUNCTION KEY OSD TALLY MODE IMD TALLY MODE TALLY SOURCE STANDARD...
  • Page 54 Functionality of the Main Menu Default Items Domain Range Description Value Set the ID number for IMD ID 0~255 each monitor Set an IMD name for IMD NAME XXXXXXXX each screen. 2400/4800/9600/19200 Select a baud rate for BAUD RATE 38400 /38400/57600/115200 communication.
  • Page 55: Key Inhibit Menu

    Functionality of the Main Menu 5.1.12 KEY INHIBIT Menu The KEY INHIBIT menu items are used to adjust the parameters displayed on the screen, the menu items are as shown in Figure 5.1-20: MAIN KEY INHIBIT KEY INHIBIT STATUS INPUT SELECT MARKER AUDIO DISPALY...
  • Page 56: Menu Settings

    Functionality of the Main Menu 5.2 Menu Settings When checking or modifying the value of the menu item, cooperating with the following buttons: MENU, UP, DOWN, ENTER. Operations to the Main menu  Display the Main Menu Press MENU button to enter into the main menu, it displays at the top left corner of the screen.
  • Page 57 Functionality of the Main Menu Operations to sub-menu item  Display the sub-menu item After display the Main menu, press UP or DOWN button to select a menu item, and the right part displays its sub-menu items according to the current selected menu item. ...
  • Page 58 Functionality of the Main Menu  The value in white color is modifiable, and the value in blue color is unmodifiable. Selecting the Menu Language You can select one of languages (English or Chinese) for displaying the menu. The default language for the menu is ENGLISH. The following will teach you how to switch to Chinese.
  • Page 59 Functionality of the Main Menu shown in Figure 5.2-4, press ENTER button to confirm the modification. 主菜单 系统配置 快速模式 关闭 状态显示 输入设置 电影模式检测 关闭 标记设置 子画面类型 音频设置 子画面输入源 SDI1 显示设置 小 PIP大小 隐藏字幕 右下 PIP位置 系统配置 背光 色彩配置 自动关机 关闭 功能键设置...
  • Page 61: Chapter 6 Network Control

    Network Control Chapter 6 Network Control FRM-173 supports network interface. Connect a computer with FRM-173 through this interface to achieve the network control to FRM-173.  The network address of the computer which is connected with FRM-173 and the network address of FRM-173 must be in the same segment. This chapter will introduce how to set and check the parameters of FRM-173 in Internet Explorer.
  • Page 62: Menu Control

    Network Control 6.2 Menu Control Open the management interface as shown in Figure 6.2-1, the menu items listed in the left part are almost as the same as the main menu items. Figure 6.2-1 Management Interface As shown in Figure 6.2-1, the management interface is divided into the following parts: Input Source Selection Button It is used to selecting an input source as the input signal, such as: SDI1,...
  • Page 63: Adjust Menu

    Network Control Parameter list It shows the parameter names, values and operation buttons of the selected navigation menu, as shown in the red rectangle in Figure 6.2-2. The title in the yellow rectangle of the parameter list and the parameter list will change with the navigation menu when switched.
  • Page 64 Network Control adjust parameters, as shown in Figure 6.2-5: Figure 6.2-3 ADJUST Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 6.2-3: Table 6.2-1 The Description of ADJUST Menu Items Items Default Value Domain Range Description Adjust...
  • Page 65: Video Display Menu

    Network Control Items Default Value Domain Range Description picture displaying mode in full WIN SOURCE MAIN MAIN/SUB mode or in sub-picture mode VOLUME 0~31 Adjust the volume 6.2.2 VIDEO DISPLAY Menu It will introduce VIDEO DISPLAY menu. Click VIDEO DISPLAY button at the left navigation menu list, it will display the video display parameters, as shown in Figure 6.2-5: Figure 6.2-4 VIDEO DISPLAY Menu The relationship of Items, Default Value, Domain Range and Description...
  • Page 66: Other Menus

    Network Control Figure 6.2-5 System Menu The relationship of Items, Default Value, Domain Range and Description of the sub-item is shown in Table 6.2-3: Table 6.2-3 The Description of System Menu Items Domain Items Default Value Description Range 192.168.1.86 IP address MASK 255.255.255.0 Subnet mask...
  • Page 67: Parameter Settings

    Network Control the menu items in the Main menu on screen, there will be no further description about their meanings and value range in this chapter, refer to “Chapter 5 Functionality of the Main Menu” for the details about STATUS, VIDEO CONFIG, AUDIO CONFIG, MARKER, DISPLAY, USER CONFIG, and COLOR TEMPERATURE.
  • Page 68 Network Control MAIN AUDIO AUDIO SOURCE AUDIO1 STATUS INPUT SELECT SPEAK OUT L EBD CH1 MARKER SPEAK OUT R EBD CH1 AUDIO AUDIO METER DISPALY METER SELECT CH1-2 CLOSE CAPTION METER DIRECTION HORIZONTAL CONFIG METER POSITION COLOR TEMP METER DIS MODE MODE1 FUNCTION KEY REF LEVEL...
  • Page 69 Network Control Figure 6.3-4 Modify the Value of a Parameter  The volume can be checked and modified in adjust menu on screen adjustment, or in Volume item of ADJUST menu in management interface. MAIN AUDIO AUDIO SOURCE AUDIO1 STATUS INPUT SELECT SPEAK OUT L EBD CH1...
  • Page 70 Network Control Likewise, if you modify the value of a parameter on screen menu first, you may check the same changing result in management interface through network connection.
  • Page 71: Chapter 7 Specifications

    Specifications Chapter 7 Specifications Product detailed information Specification Values LCD Dimension 17.3”,421.81(H) x 264.31(V) x 64.8(D) Aspect Ratio 16:9 Display Area(mm) 381.888(H)×214.812(V) Viewing Angle 100 (H) x 80 (V)min/160 (H) x140 (V)Typ Color Depth 262K colors (6-bit) Resolution 1920(H)×1080(V) Pixel Pitch(mm) 0.1989(H)×0.1989(V) 500:1 Contrast...
  • Page 72 Specifications Specification Values 3G-SDI /HD-SDI /SDI-SDI Input/Output SMPTE 424M, SMPTE 292M, SMPTE 259M, Signal Type SMPTE 297M Connector BNC per IEC 169-8 Impedance 75Ω >18 dB 5 to 270 MHz Return Loss >15 dB 270 MHz to 1.5 GHz >10 dB up to 3 GHz Maximum Signal Level 800 mV pk-pk 10% Signal Amplitude...
  • Page 73 Specifications OVERSCAN NATIVE FULL/NORMAL Refresh Color OUTPUT Rate Matrix Input Output Input Output INPUT ALL NORMAL 1024X768 1024X768 720P24 1216X684 1366X768 1280x720 1280x720 1280x720 1366X768 720P25 1216X684 1366X768 1280x720 1280x720 1280x720 1366X768 720P30 1216X684 1366X768 1280x720 1280x720 1280x720 1366X768 720P50 1216X684 1366X768 1280x720...
  • Page 74 Specifications Figure 7-1 Front Panel(Unit: mm) Figure 7-2 Rear Panel(Unit: mm)
  • Page 75 Specifications Figure 7-3 Side View-Not In Rack(Unit: mm) Figure 7-4 Side View-In Rack(Unit: mm)  Specifications are subject to change without notice. ------------------No Text Below------------------...
  • Page 77 FOR MORE INFORMATION PLEASE VISIT: http://www.osee-dig.com/ OSEE TECHNOLOGY CO., LTD. No.22 Building, No.68 zone, Beiqing Road, Haidian District, Beijing, China Tel: (+86) 010-62434168, Fax: (+86) 010-62434169 E-mail: sales@osee-dig.com...