Specifications; General Specifications; Optical Transmitter; Optical Receiver - Fluke DSP-FTA440S User Manual

Fiber test adapter
Table of Contents

Advertisement

DSP-FTA410
Users Manual

Specifications

General Specifications

Power supply: ±6 V supplied by the DSP-4000 test tool.
Temperature range: Operating: 0 ºC to +40 ºC; Storage: -10 ºC to +60 ºC
Warm-up time: 5 minutes
Humidity range: Operating: 0 % to 75 % RH, non-condensing
Storage: 0 % to 95 % RH, non-condensing
Certifications:
Dimensions: 3.3" x 4.6" x 1.9" (8.3 cm x 11.6 cm x 4.7 cm)
Weight: 7.6 oz (215 g)

Optical Transmitter

Connector: SC, multimode
Emitter type: LED
Wavelengths: 850 nm and 1300 nm
Power output at 850 nm and 1300 nm: -20 dBm (10 µW), typical
(into 62.5/125 µm fiber)
Power output stability (8 hours) at 850 nm and 1300 nm: ±0.25 dB at 23 °C

Optical Receiver

Power measurement accuracy: ±0.25 dBm at 23 °C, 45 % RH to 75 % RH, -20
dBm for 850 nm and 1300 nm, -10 dBm for 1550 nm
Connector: SC, multimode or singlemode
Detector type: Germanium
Calibrated wavelengths: 850 nm, 1300 nm, 1310 nm, and 1550 nm
Measurement range: 0 dBm to -40 dBm
Power measurement linearity: ±0.25 dB at 23 °C
Length measurement accuracy: ±1.5 m plus 2 % of length