3 Pull the RJ45 jacks off the circuit boards (Figure 3), being careful not to stress the
boards.
4 Align the new RJ45 jacks on the connectors on the circuit boards. Note in Figure 3 how
the insulation displacement connectors in the jacks slide into the connectors on the
circuit boards.
5 Place the boards on a hard, flat surface; then push the RJ45 jacks onto the connectors
on the boards. If firm pressure does not push the jack onto the connectors, realign the
jack on the connectors before trying again.
6 Reassemble the cases.
7 If the performance of the adapters was characterized when the adapters were new,
use the results and the reference patch cord to check the adapters' performance. See
Appendix A.
Insulation displacement
connectors in the RJ45 jack

Specifications

The DTX CableAnalyzer testers are guaranteed to meet these accuracy requirements at
these categories of permanent link and channel pass/fail limits:
They meet Level IIe requirements at Cat 5e limits.
They meet Level III requirements at Cat 6 limits.
They meet Level IIIe requirements at Cat 6A limits.
Refer to the DTX CableAnalyzer Series Technical Reference Handbook for details.