Panasonic CS-RZ35WKRW Service Manual page 46

Hide thumbs Also See for CS-RZ35WKRW:
Table of Contents

Advertisement

10.2.2
CU-RZ35WKR
NOISE FILTER
CIRCUIT
(GRN)
GRN
AC_GND
TERMINAL
BLK
BOARD
YLW
1
1
ORG
4
2
DCH
G1
RED
C501
3
1000p
BRW
C
3k V
24V_1
7
DRM
CN-OPT
D501
(WHT)
1A5
1SS355
D502
1SS355
D503
1SS355
D504
1SS355
D505
G1
G1
SINGLE PHASE POWER SUPPLY
TO INDOOR UNIT
L
N
1
2
BLK
WHT
SOUND PROOF
BOARD
CN-DEMAND
DCH
DCH
DCH
C506
C503
C505
1000p
1000p
1000p
3k V
3k V
3k V
3
2
*C504
NONE
4
LF501
1
G1
24V_1
PC501
*R503
1
4
R507
*D506
NONE
10k
NONE
*C507
1/10 W
NONE
2
3
R504
TLP421
24V_1
2k
(BL.J)
ZD502
1W
30V
*R505
R508
*D507
PC502
1
4
NONE
10k
NONE
1/10 W
*C508
NONE
2
3
R506
TLP421
2k
(BL.J)
ZD501
1W
30V
ELECTRONIC CONTROLLER
Sensor (Thermistor)
70
60
50
40
30
2
20
10
0
-10
TERMINAL
3
BOARD
GRY
RAT2
DATA
(GRY)
(RED)
COMMUNICATION
CIRCUIT
FUSE 103
AC-BLK
(20A 250V)
(BLK)
NOISE FILTER
CIRCUIT
AC-WHT
(WHT)
GRN
FG1
(GRN)
GRN
RECTIFICATION
FG2
CIRCUIT
(GRN)
SWITCHING POWER
SUPPLY CIRCUIT
24V
CN-V1
(WHT)
1
RED
1
BLK
CN-PWR
2
2
G10_1
(WHT)
1
1
WHT
WHT
WHT
3
3
CN-DEMAND
(WHT)
(WHT)
ELECTRONIC CONTROLLER (MAIN)
Compressor Temp. Sensor
Characteristics
(Thermistor) Characteristics
70
1
Outdoor Air Sensor
2
Outdoor Heat Exchanger
60
Sensor
50
40
1
30
20
10
0
0
10
20
30
40
50
20
40
60
80
100
120
o
o
Temperature (
C)
Temperature (
C)
46
REACTOR
GRY
RAT1
5V
(GRY)
FUSE 2
FUSE 3
R11
(20A 250V)
(20A 250V)
15.8k
*R468
1%
PFC CIRCUIT
10k
X
C9
*R465
*R466
1u
RECTIFICATION
20k
12k
10V
CIRCUIT
G5
FUSE 104
T3.15A L250V
G5
R1
4.99k
1%
G5
*D23
4V
A
E
B
*Q24
C
*R117
*R130
*R131
7
10
6
11
*R134
5
12
4
13
3
14
2
15
1
16
KID65003AP/P
G4
IC4
Q1
U (RED)
U
P
V (BLU)
V
N
W (YLW)
W
R600
FUSE 101
1k
T3.15A L250V
C401
0.01u
50V
IC25
10
W
14
U
V
16
R14
5V
10k
G6
CN-S
2
1
The unit turn to the Rated Frequency Cooling Operation by short-circuiting CN-S after applying power between the terminal 1 and 2.
DC FM
Operation of the compressor and the outdoor fan motor can be checked by applying power after short-circuiting CN-S.
CN-MTR1
1
Feedback output (0 - 5Vdc pulse)
2
5Vdc
3
GND
CN-MTR2 (Measure winding resistance / voltage)
1
W
~80 ohm / 15Vdc
3
U
~80 ohm / 15Vdc
5
V
~80 ohm / 15Vdc
140
CN-TH1 (Measure resistance)
1-2
Outdoor air intake sensor (15KΩ ±5% at 25°C)
3-4
Pipe temp sensor (4.96KΩ ±5% at 25°C)
CN-TANK (Measure resistance)
1-3
Comp temp sensor (50KΩ ±5% at 25°C)
CN-HOT
Measure resistance of v-coil CN-HOT
1-3
18Ω at 20°C
Measure voltage on PCB
during 4-way valve ON
1.8Vdc - 15Vdc
OFF
-
CN-PWR
Measure voltage
1-2
24Vdc
CN-DEMAND
Measure voltage
1-3
24Vdc
IPM (Input / Output)
Measure voltage
P & N, N-U,
280Vdc - 340Vdc
N-V, N-W
R12
15k
1%
KY
+
X
C88
C10
220u
1u
10V
10V
OUTDOOR AIR TEMP. SENSOR (THERMISTOR)
G5
1
4
PIPING TEMP. SENSOR (THERMISTOR)
CN–TH1
(WHT)
C5
1u
KB
10V 5V
CN–TANK
(WHT)
G5
1
COMPRESSOR TEMP. SENSOR (THERMISTOR)
3
1
ELECTRO-MAGNETIC COIL
(4-WAY VALVE)
K
3
CN–HOT
*D20
(WHT)
5V
G4
*C174
G4
1
M
6
CN–STM
(WHT)
RED
BLU
MS
3~
YLW
COMPRESSOR
1
WHT
PNK
BLK
3
B
5V
CN-MTR1
G5
(RED)
C400
10u
25V
A
1
RED
G5
3
YLW
MS
3~
BLU
5
CN-MTR2
(WHT)
FAN MOTOR

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents