Panasonic CS-RZ35WKRW Service Manual page 130

Hide thumbs Also See for CS-RZ35WKRW:
Table of Contents

Advertisement

18.4.6
H19 (Indoor Fan Motor – DC Motor Mechanism Locked)
Malfunction Decision Conditions
The rotation speed detected by the Hall IC during fan motor operation is used to determine abnormal fan motor
(feedback of rotation > 2550 rpm or < 50 rpm).
Malfunction Caused
Operation stops due to short circuit inside the fan motor winding.
Operation stops due to breaking of wire inside the fan motor.
Operation stops due to breaking of fan motor lead wires.
Operation stops due to Hall IC malfunction.
Operation error due to faulty indoor unit PCB.
Troubleshooting
When abnormality indication starts again.
Turn off power supply and rotate fan by hand.
Does fan rotate smoothly?
Turn power supply on and operate fan.
Does it rotate?
Turn off power supply and disconnect fan motor connector,
then turn power on.
Check the output of fan motor from indoor PCB.
Is the motor power supply voltage 310~340 Vdc (pin 1 & 4)
generated?
Is the motor control voltage 14.6~17.0 Vdc (pin 5 & 4)
generated?
Operate the fan, is the rotation command voltage 3~5 Vdc
(pin 7 & 4) generated?
YES
NO
YES
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.
NO
Replace fan motor.
YES
Check the rotation feedback output from fan motor.
Operate the fan motor, is the rotation feedback
voltage ~8.0 Vdc (pin 6 & 4) generated?
NO
NO
NO
Replace indoor PCB.
Replace fan motor.
130
NO
YES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents