21.2 Heat Mode Outdoor Air Temperature Characteristic

Condition
- Indoor room temperature: 20°C DryBulb/-°C Wet Bulb
- Unit setting: Standard piping length, forced heating at 30°C, Hi fan
- Compressor frequency: Rated for Heating operation
- Piping length: 5m
- Voltage: 230-240V
21.2.1
CS-RZ25WKRW CU-RZ25WKR
42.000
40.000
38.000
36.000
34.000
32.000
30.000
28.000
26.000
24.000
-15
-10
4.000
3.500
3.000
2.500
2.000
1.500
1.000
-15
-10
3.600
3.400
3.200
3.000
2.800
2.600
2.400
2.200
2.000
-15
-10
3.000
2.800
2.600
2.400
2.200
2.000
1.800
1.600
-15
-10
-5
0
5
10
Outdoor Air Temperature (°C)
-5
0
5
10
Outdoor Air Temperature (°C)
-5
0
5
10
Outdoor Air Temperature (°C)
-5
0
5
10
Outdoor Air Temperature (°C)
230
240
15
20
25
15
20
25
15
20
25
435.000
406.000
377.000
348.000
319.000
290.000
261.000
232.000
15
20
25
168
Indoor Discharge
Outdoor
Air Temperature
Temperature (°C)
(°C)
-15
24.72
-7
29.89
2
31.37
7
33.73
24
41.99
Outdoor
Heating Capacity
Temperature (°C)
(kW)
-15
1.256
-7
2.228
2
2.248
7
3.000
24
3.599
Current (A)
Outdoor
Temperature (°C)
230V
-15
2.28
-7
2.61
2
2.80
7
3.00
24
3.50
Gas Side Piping
Outdoor
Pressure
Temperature (°C)
(MPa)
-15
1.603
-7
2.010
2
2.168
7
2.258
24
2.972
240V
2.18
2.51
2.70
2.90
3.40
(Psi)
232.000
291.000
314.000
327.000
431.000