17.3.2
Operation mode during Cooling Only and Heating Only Operation
The table below shows the operation mode comparison when Heating Only Operation Mode Activated and
Deactivated.
Operation mode
Cooling Only Operation Mode Activated
After 30s sampling, regardless of indoor
intake or outdoor intake temperature
AUTO
judgement, the unit will run Cooling or
DRY operation.
The unit will stop and Power LED
HEAT
blinking.
COOL
The unit will run Cooling operation.
DRY
The unit will run DRY operation.
The unit will run Force Cooling
Force Cooling
operation.
The unit will run Force Cooling
Force Heating
operation.
The unit will turn ON by the timer and
run Auto Operation. After 30s sampling,
AUTO
regardless of indoor intake or outdoor
(with Timer)
intake temperature judgement, the unit
will run Cooling or DRY operation.
HEAT
The unit will not turn ON by the Timer.
(with Timer)
Power LED blinking.
COOL
The unit will turn ON by the Timer and
with Timer)
run Cooling operation.
DRY
The unit will turn ON by the Timer and
(with Timer)
run DRY operation.
The unit will operate according to
Cooling
specified Cooling test mode operation
Test mode
parameter.
Heating
The unit will stop and Power LED
Test mode
blinking.
Heating Only Operation Mode Activated
After 30s sampling, regardless of indoor
intake or outdoor intake temperature
judgement, the unit will run Heating
operation.
The unit will run Heating operation.
The unit will stop and Power LED
blinking.
The unit will stop and Power LED
blinking.
The unit will run Force Cooling operation
for X_CTRYTM [15] minutes.
The unit will run Force Heating
operation.
The unit will turn ON by the timer and
run Auto Operation. After 30s sampling,
regardless of indoor intake or outdoor
intake temperature judgement, the unit
will run Heating operation.
The unit will turn ON by the timer and
run Heating Operation.
The unit will turn ON by the Timer.
Power LED blinking.
The unit will turn ON by the Timer.
Power LED blinking.
The unit will stop and Power LED
blinking.
The unit will operate according to
specified Heating test mode operation
parameter.
112
Normal Operation Mode
After 30s sampling, the unit will judge
the operation mode base on remote
controller temperature setting and
Indoor Intake Sensor (New Auto Mode)
or Outdoor Intake Sensor (Old Auto
Mode).
The unit will run Heating operation.
The unit will run Cooling operation.
The unit will run Dry operation.
The unit will run Force Cooling
operation.
The unit will run Force Heating
operation.
The unit will turn ON by the timer and
run Auto Operation. After 30s sampling,
the unit will judge the operation mode
base on remote controller temperature
setting and Indoor Intake Sensor (New
Auto Mode) or Outdoor Intake Sensor
(Old Auto Mode).
The unit will turn ON by the timer and
run Heating Operation.
The unit will turn ON by the timer and
run Cooling Operation.
The unit will turn ON by the timer and
run Cooling Dry Operation.
The unit will operate according to
specified Cooling test mode operation
parameter.
The unit will operate according to
specified Heating test mode operation
parameter.