CONSTRUCTION OF
ENCLOSURE
WARNING:
All appliances must have a gas shutoff
on the outside of the fi re pit to allow for
emergency shut off and maintenance.
WARNING:
For electronic ignition models, there must
be an electrical shutoff (wall switch or
breaker) on the exterior of the appliance
or on adjacent structure to allow for
emergency shutdown and maintenance.
Verify correct power supply.
If located on the vessel, key valve should be mounted
below the plate and through the side wall of the vessel. Key
valves may be mounted remotely or on adjacent surfaces.
Always use proper materials and construction for gas sup-
ply, power and enclosure. Materials must be non-combusti-
ble in both initial installations as well as over time.
For electronic ignition models requiring power supply — a
qualifi ed, licensed electrician must install power supply.
The unit may be hardwired or an outdoor NEMA rated
GFCI Receptacle outlet can be installed on the interior of
the enclosure above grade to supply power to system.
Minimum ventilation requirement: Incorporate 1 vent
on at least two opposing sides (2 vents total) at a
minimum size of 18 sq. inches each (Example: 3"x 6" or
larger). Installation of the vents in the mid to lower area
of the enclosure is recommended. Ventilation allows for
heat and/or residual fuel to escape. Failure to properly
vent enclosure may result in the appliance overheating
or explosion. Overheating could lead to heat damage
to internal components. Some enclosures may require
more ventilation based on material, size, and extended
use. Always consult with local municipality regarding
any code requirements.
The interior space of the enclosure cannot be fi lled with
any material (gravel, crushed rock, concrete, etc.).
The appliance assembly should be recessed 4"- 6" from
Ready-to-Finish
Kits come with Fire
Pit Vent Kit (FPVK).
Vents do not come
pre-installed on
Ready-to-Finish Kit
as placement and
installation depends
on veneer. Vents
to be installed by
contractor on site.
www.Warming-Trends.com | 303 346 2224 | orders@warming-trends.com
the top of the enclosure to protect fl ame from excessive
wind. Some conditions may require deeper recession.
It is the responsibility of the installer to provide proper in-
stallation to allow for easy accessibility for service and/or
repairs. Installer must not build capstone inner ledge over
outer lip of plates or pans (unless access panel door or
alternate access is incorporated). Building capstone inner
ledge over outer edge of plates or pans will impede ac-
cess to system and result in the need to crack or remove
capstones to gain access. Warming Trends is not responsi-
ble for damage to enclosure for any reason whatsoever.
WARNING: These instructions do not
apply to vessels or appliances with self
contained propane gas supply systems.
Appliances or vessels with self contained
propane gas supply systems have
additional specifi c requirements which
must be identifi ed and met by the vessel
installer or manufacturer. Please consult
with a qualifi ed installer for guidance and
required installation procedures.