Advertisement

Quick Links

SCAN TO VISIT
WARMING-TRENDS.COM
Warming_Trends_Instruction_Manual_V3.8.indd 1
Warming_Trends_Instruction_Manual_V3.8.indd 1
OWNER'S GUIDE AND
INSTRUCTION MANUAL
THANK YOU FOR YOUR PURCHASE!
www.warming-trends.com/patents
PATENTED
Version 3.8
SCAN TO SEE AN UPDATED
ICC-ES LIST
2/20/2024 10:44:52 AM
2/20/2024 10:44:52 AM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CFB60 and is the answer not in the manual?

Questions and answers

Summary of Contents for Warming Trends CFB60

  • Page 1 OWNER’S GUIDE AND INSTRUCTION MANUAL THANK YOU FOR YOUR PURCHASE! SCAN TO VISIT SCAN TO SEE AN UPDATED PATENTED WARMING-TRENDS.COM www.warming-trends.com/patents ICC-ES LIST Version 3.8 Warming_Trends_Instruction_Manual_V3.8.indd 1 Warming_Trends_Instruction_Manual_V3.8.indd 1 2/20/2024 10:44:52 AM 2/20/2024 10:44:52 AM...
  • Page 2: Important Product Warnings

    I M P O R TA N T P R O D U C T W A R N I N G S A V E R T I S S E M E N T S I M P O R TA N T S C O N C E R N A N T L E S P R O D U I T S DANGER DANGER RISQUE D’INCENDIE OU D’EXPLOSION...
  • Page 3: Table Of Contents

    Model # CFBO180 NG/LP with PBIK Model # CFBH240 NG/LP with 24VIKHC Model # CFBL150 NG/LP with MERC MATCH LIT Model # CFB60 NG/LP as match lit Model # CFBO280 NG/LP with PBIK Model # CFBH260 NG/LP with 24VIKHC Model # CFBL170 NG/LP with MERC Minimum and Maximum Gas Inlet Pressures ...........................
  • Page 4: General Information

    Warming Trends is not responsible for damage due to improperly installed or operated units. Installers must leave this user guide with the end user. Instructions are updated as needed, and it is the installer or owners’ responsibility...
  • Page 5: Location Considerations

    • Choose a location that allows easy access for installation and maintenance of the fire feature. to system and result in the need to crack or remove capstones to gain access. Warming Trends is not responsible for • Pick a location that allows sufficient horizontal room to enjoy the appliance while allowing a safe distance from damage to enclosure for any reason whatsoever.
  • Page 6: Fire Feature Clearance Diagram

    F I R E F E AT U R E C L E A R A N C E D I A G R A M F I R E F E AT U R E C L E A R A N C E D I A G R A M - M E R C U R Y I G N I T I O N S Y S T E M Vertical clearance of 120”...
  • Page 7: Critical Dimensions - Construction & 24V Electronic Ignitions

    See Clearance Diagrams starting valve must be disconnected from the gas supply on page 10 for placement. Warming Trends® is not piping system during any pressure testing of that responsible for any damages to the capstone.
  • Page 8: General Installation Instructions

    G E N E R A L I N S TA L L AT I O N I N S T R U C T I O N S - C O N T I N U E D LEAVE THIS CONNECTION DIAGRAM WITH END USER. M AT C H L I T S Y S T E M : C O N N E C T I O N D I A G R A M S the enclosure is recommended.
  • Page 9 M AT C H L I T: 2 4 9 K B T U S Y S T E M S A N D B E L O W - C O N T I N U E D M AT C H L I T: C O N N E C T I O N D I A G R A M S 4.
  • Page 10 M AT C H L I T: I N S TA L L AT I O N 2 5 0 K - 3 0 0 K + B T U - C O N T I N U E D 2 4 V O LT: C O N N E C T I O N D I A G R A M S 4.
  • Page 11 2 4 V O LT: I N S TA L L AT I O N U P T O 2 4 9 K B T U S Y S T E M S - C O N T I N U E D STEP 5 2 4 V O LT: C O N N E C T I O N D I A G R A M S 250K - 300K+ BTU SYSTEMS...
  • Page 12 2 4 V O LT 2 5 0 K - 3 0 0 K + B T U S Y S T E M S : I N S TA L L AT I O N - C O N T I N U E D 2 4 V O LT 2 5 0 K - 3 0 0 K + B T U S Y S T E M S : I N S TA L L AT I O N C O N T I N U E D 6.
  • Page 13: Installation Instructions

    Stem than .125” away from inside edge The Warming Trends plate/pan that was included with your Order should have pre-cut pilot assembly knockouts for of jet. Drill hole where base of spark various burners. The burner type and size are etched into the plate/pan next to the knockout for that burner’s pilot igniter sits.
  • Page 14 4. CONNECTING THE FLEX LINE TO THE VALVE ASSEMBLY Please Note: Warming Trends sells two Flex Line Kits for the Mercury Ignition, depending on the BTU supply of the burner. The FKM1 has one (1) flex line and fits burners up to 249 BTUs {See Photo 6}. The FKM2 has two (2) flex lines and fits burners 250 BTUs or more {See photo 7}.
  • Page 15 M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D FKM2 INSTRUCTIONS: 4.2 The Flex Line is provided with a male flare hose adapter loosely attached.
  • Page 16 M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D 4.7 Apply joint compound, thread sealant, or plumbing tape to the 3/4’’...
  • Page 17 M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D 6.3 Apply joint compound, thread sealant, or plumbing tape to the threads of the ½”...
  • Page 18: Warning Label

    W A R N I N G L A B E L M E R C U R Y I G N I T I O N : I N S TA L L AT I O N C O N T I N U E D 6.6 Apply joint compound, thread sealant, or plumbing tape to the threads to the 3/4”...
  • Page 19: Lighting Instructions

    O P E R AT I N G I N S T R U C T I O N S L I G H T I N G I N S T R U C T I O N S : M E R C U R Y I G N I T I O N Keep the area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.
  • Page 20: General Maintenance

    10. If the flame will not stay lit after several attempts, turn the key valve or gas control to the off position and call your Thank you for your purchase of a FireStorm® Steel Gas Log from Warming Trends. We appreciate your business and hope local technician or gas supplier for service prior to re-attempting to operate your appliance.
  • Page 21: Warranty

    CROSSFIRE™ burner has an obstruction - Confirm there is no debris blocking gas orifice jets in burner, purge system must be replaced due to a defect or malfunction of the system, Warming Trends® will repair or replace the system at no cost for the first year. In the event a 24VIK or 3VIK system fails after the first year from date of purchase and within two years from date of purchase, Warming Trends will repair or replace the system for a cost of 50% of the current list price.
  • Page 22: Prop 65 Warning

    Californians purchase, in their homes or workplaces, or that are released into the environment. For more information about Warming Trends products, please visit us at www.Warming-Trends.com. Prop 65 enables Californians to make informed decisions about their exposures to these chemicals.
  • Page 23 CONGRATULATIONS ON YOUR PURCHASE! We appreciate your business and look forward to seeing your finished project. Tag us on Instagram! @WarmingTrends SCAN TO VIEW OUR INSTAGRAM Warming-Trends.com | 303 346 2224 | Orders@Warming-Trends.com Warming_Trends_Instruction_Manual_V3.8.indd 44 Warming_Trends_Instruction_Manual_V3.8.indd 44 2/20/2024 10:46:45 AM 2/20/2024 10:46:45 AM...

Table of Contents